1. HALL Adjustment

For detecting the position of the lens iris, adjust AMP gain and
offset.
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value 1
Specified Value 2
Note1: Displayed data of page 1 of the adjustment remote commander.
1 : 00 : XX
Adjusting method:
Order Page Address Data
1
0
01
2
6
94
3
6
95
4
6
01
6D
5
6
02
6
6
01
Note2: The adjustment data will be automatically input to page: F, address:
30, 31, 32.
Checking method:
Order Page Address Data
1
0
03
2
6
01
3
1
4
6
01
5
1
Processing after Completing Adjustments:
Order Page Address Data
1
6
94
2
6
95
3
6
01
4
0
03
5
0
01
Not required
Display data of page 1 (Note1)
Adjustment remote commander
F
30, 31, 32
86 to 8A
15 to 19
IRIS display data
Procedure
01
Set the data.
88
Set the data.
17
Set the data.
Set the data, and press PAUSE
button.
Check that the data changes to
"01". (Note2)
00
Set the data, and press PAUSE
button.
Procedure
03
Set the data.
01
Set the data, and press PAUSE
button.
Check that the IRIS display data
(Note1) satisfies the specified
value 1.
03
Set the data, and press PAUSE
button.
Check that the IRIS display data
(Note1) satisfies the specified
value.2.
Procedure
00
Set the data.
00
Set the data.
00
Set the data, and press PAUSE
button.
00
Set the data.
00
Set the data.
5-12