Martin Professional MiniMAC Wash User Manual page 24

Table of Contents

Advertisement

1 Select any one fixture to be the master. On this fixture only, scroll to
menu, press [enter], scroll to
2 On all slave fixtures, scroll to
press [enter], scroll to
3 Plug a data cable into the OUT socket of the first fixture
and the IN socket of the next fixture. Repeat as required
to connect up to 32 MiniMACs (Profiles and Washes).
4 Insert a female termination plug (P/N 91613018) into the
IN socket of the first fixture. Insert a male termination plug
(P/N 91613017) into the OUT socket of the last fixture. A
termination plug is an XLR connector with a 120 ohm,
0.25 W resistor soldered across pins 2 and 3.
5 On all fixtures, scroll to
A ut
or
as expected, verify that Programmed Stand-alone mode
is disabled, i.e., that
6 Set the trigger and pan/tilt options using the control panel on the master fixture. Set
the color and gobo options on the slave fixtures. See Table 6. Note: The inverse pan
and inverse tilt personalities may also be used to modify behavior. See Table 4.
7 To stop operation, simply disconnect the fixture from power. To disable stand-alone
operation, set
To operate via remote control
1 Connect up to 32 MiniMACs to the MC-1 remote control as described under "To
connect for controller operation" on page 21. Apply power to the fixtures and the
remote control.
2 (Optional) Set the pan/tilt range and speed on each fixture. For synchronized
operation, the speed setting must be identical on all fixtures. The inverse pan and
inverse tilt personalities may also be used to modify behavior. (See Table 4.)
3 For non-synchronized action at different speeds, press the Slow, Medium, Fast, and
Random Stand-alone keys. For synchronized action at different speeds, press the
Stand-alone key for the desired speed (slow, medium, fast, or random) and then
press the Music trig key. To freeze action press the active control key. To strobe
fixtures, press and hold Strobe. Normal operation resumes when the key is released.
To send a single trigger pulse press Manual trig. This may be used on its own, with
no function selected, or to supplement sound-activated triggers. To black out all
fixtures, press Blackout. Press it again to return to normal operation.
4 If fixtures do not respond, verify that Programmed Stand-alone mode is disabled, i.e.,
Ct r
that
24
Ctr
rE C
, and press [enter].
En A
, press [enter], scroll to
, and press [enter]. (If a fixture does not respond
Ctr
r un
/
EnA
O FF
to
.
run
OF F
/
is set to
Automatic Stand-alone
, press [enter], scroll to
SA
in the main menu, press [enter], scroll to
OF F
is set to
.)
.
SA
in the main
S nd
, and press [enter].
Female
Termination Plug
Female XLR
1
2
120
3
On
P/N 91613018
Ctr
,

Advertisement

Table of Contents
loading

This manual is also suitable for:

Minimac profile

Table of Contents