Gaylord Ventilator model numbers are made up of an alphabetic prefix followed by a series of alphabetic
and/or numeric suffixes to designate the style of ventilator and various options. Sequence of model num-
bers is as follows.
1._____
2._____
Series
Damper
Type
Definition of Prefixes and Suffixes
1. Series
ELXC ........................... High Efficiency Water Wash Ventilator incorporating XGS Extractors.
ELXC-UVi ................. High Efficiency Water Wash Ventilator incorporating XGS Extractors and UV
2. Damper Type
GFBD......................... Gaylord Fire Balancing Damper. Has an electric, thermostatically activated Fire/
GEBD ........................ Gaylord Electric Balancing Damper. Has an electric balancing damper located at
GBD .......................... Gaylord Balancing Damper. Mechanical balancing damper located at the duct
GBD-ES ..................... Gaylord Balancing Damper. Mechanical balancing damper located at the duct
ND ............................ No Damper.
3. Style
Blank .................. Wall mounted canopy style.
CL ........................ Island style for single line of cooking equipment using one extraction chamber
(Light to Medium Duty only).
BBC-CL ............... Island style for single line of equipment using one extraction chamber with one
common exhaust duct.
BBC ..................... Island style for double line of cooking equipment using on one extraction chamber and
one common exhaust duct.
BB ........................ Island style for double line of equipment using two extraction chambers and two
separate exhaust ducts
4. Front Lip Design (Front lower edge of the hood)
Blank .....................
S ............................

Model Number Sequence

3._____
4._____
Style
Front Lip
Design
(Option)
treatment.
Balancing damper located at the duct collar with back draft feature. 250°F N.C.
Thermostat standard.
the duct collar with back draft feature.
collar with internal set.
collar with external set.
Facetted front design with 6 inch return flange. (3 Break or greater at front lip)
(CL models to have a maximum of 9").
Square front with 6 inch "Super Capture" lip.
5.______
6._____
Apron
Canopy
Design (If
Front
Applicable)
Height
(Option)
1-3
Chapter 1 - Introduction
7._____
8.______ 9._____
Solid fuel AutoStart
Hood
Depth