Model Number Sequence - GAYLORD CG3-UVi-SPC Series Technical Manual

Table of Contents

Advertisement

Chapter 1- Introduction, Page 1-4__________________________________________________________

Model Number Sequence

The CG3-UVi-SPC Series model numbers are made up of an alphabetic prefix followed by a series of
alphabetic and/or numeric suffixes to designate the style of ventilator and various options. Sequence of
model numbers is as follows.
1._____
2._____
Series
Damper
Type
Explanation of Prefixes and Suffixes
1. Series
CG3-UVi-SPC ............ Water Wash Ventilator with ultraviolet light and smoke pollution control
2. Damper Type
Blank Space ............. Electrically activated three position damper located at air inlet slot (Refer to
FDD ........................... Same as CG3-UVi-SPC except inlet damper is fixed and has a fuse link activated
FDT ............................ Inlet damper is fixed and no damper motor, and has fuse link activated fire
FDL ........................... Same as CG3-UVi-SPC except a bracket (Fire Damper Lockout) has been added to
ND ............................ Same as CG3-UVi-SPC except inlet damper is fixed and has no fire damper (Refer
3. Style
BDL ........................... Wall mounted canopy.
BDL-BB ................. Island style for back-to-back cooking equipment using two extraction chambers
BBC ........................... Island style for back-to-back cooking equipment using two extraction chambers
BDL-DS ..................... Island style for back-to-back cooking equipment using one extraction chamber
BDL-DS-CL ............... Island style for single line of cooking equipment.
4. Profile
LP ...........................
3._____
4._____ 5.______
Style
Low
Profile
Design
(Option)
Applicable
feature.
Figure 1-5-1).
fire damper located at the duct collar (Refer to Figure 1-6-1)
damper located at the duct collar with a thermostat to detect fire to send
notification (Refer to Figure 1-5-3)
prevent the damper from closing to the fire position (Refer to Figure 1-5-2)
to Figure 1-6-2).
and two separate exhaust ducts.
with one common exhaust duct.
with two inlet slots. Has common exhaust duct.
Low Profile. Reduced height of front face of Ventilator and sloping end panels.
6._____
Style of
Custom
Built in
Air If
Make-up
Applicable
Air If
7._____
8. ______
Cold
Autostart
Water
If
Mist, If
Applicable
Applicable
9. _______
Front to
Back
Dimension
of the
Ventilator