Residual Moisture Sensor Circuit Test; T 1515, T 1520, T 1526, T 1565 C And T 1570 C Procedure; Table 6-4: T 1576 Programming Settings - Miele T 15xx Technical Information

Table of Contents

Advertisement

T 15xx Dryers
Press Start to toggle between options. Refer to Table 6-4.
3. To store the selected setting, switch the appliance off while the program
selector switch is in the desired position and the “"Rotary iron”" LED is
displaying the desired setting.
Selector Switch
Position
COTTONS Extra dry
COTTONS Normal
COTTONS Hand iron

Table 6-4: T 1576 Programming Settings

1
Factory setting (do not adjust)
6.4

Residual Moisture Sensor Circuit Test

Purpose:
This serves as a test of the complete moisture-sensing circuit between the
control module and the moisture sensor.
6.4.1

T 1515, T 1520, T 1526, T 1565 C and T 1570 C Procedure

1. Electrically connect one lifter bar and the drum body using clip leads or a wire
to simulate wet laundry and high conductivity.
2. Select “"15 mins. cool air”" in the service mode and wait approximately 60
seconds.
a. “"Cooling down”" LED lights up: Circuit is in proper working order.
b. “"Cooling down”" and “"Drying”" LEDs flash alternately: Resistance of
connection between controls and sensors is too high or is open-circuited.
3. Disconnect the wires to the drum and lifter bar at the pickup connection plug.
4. Jump the wires leading to the electronic (short-circuiting the moisture-sensing
circuit).
5. Select “"15 mins. cool air”" in service mode and wait approximately 60
seconds.
a. “"Cooling down”" LED lights up: Check circuit outside of the control
electronic (slip rings, wiring, lifter bars, sensor contacts, etc.).
b. “"Cooling down”" and “"Drying”" LEDs flash alternately: Replace the control
electronic.
6. Remove the wire jumper from inside the drum.
7. Select “"20 mins. warm air”" in service mode and wait approximately 60
seconds.
a. “"Cooling down”" LED lights up: Circuit is in proper working order.
b. “"Cooling down”" and “"Drying”" LEDs flash alternately: Circuit defective (lifter
bars, drum partially short-circuited). Resistance is < 50 M .
Function
Residual Moisture
Level
Memory Function
Anti-Crease Action
39
Technical Information
Option(s)
Status of "Rotary iron" LED
1
Standard
Off
Reduced
On
1
No
Off
Yes
On
1
No
Off
Yes
On

Advertisement

Table of Contents
loading

Table of Contents