Miele HR 1421 Installation Instructions Manual page 21

30" electric, 30" induction range 30", 36" all gas range 30", 36", 48" dual fuel range
Table of Contents

Advertisement

HR 1421; HR 1622
Position
Dimension
13" (330 mm)
6" (152 mm)
18" (547 mm)
30" (762 mm)
or 24" (609 mm) Minimum distance if the bottom of the wooden or
35 1/2"–37"
(901 - 940 mm)
30 1/16" + 1/16"
(763.6 mm +
1.58 mm)
10 13/16"
(274 mm)
approx. 4 1/2"
(115 mm)
approx. 2 13/16"
The gray areas represent the minimum distance from flammable surfaces.
The hatched areas represent the installation areas for the connections.
For island installations, 12" (305 mm) minimum distance from back of range to flammable
rear wall above countertop.
Description
Maximum depth of top cabinet
Minimum distance (left and right) to flammable
surfaces
Minimum distance to bottom edge of top cabinet
Minimum distance between the top of the cooking
area and the bottom of an unprotected wooden or
metal cabinet
metal cabinet is not protected by less than 1/4-
inch-thick, flame-retardant cardboard, which is
covered and protected by no less than No. 28
MSG sheet steel, 0.015-inch-thick stainless sheet
steel, or covered with 0.024-inch-thick aluminum
or 0.020-inch-thick sheet copper.
Distance from floor to cooktop surface
Width of cabinet opening
approx.
Maximum connection width right and left
Maximum connection height
Maximum connection depth
(72 mm)
Electric Range dimensions
21