Anti-tip device
Installation dimensions of
locking bolt
Anti-tip device, front view
Model
HR 1421
HR 1622
(762 mm)
HR 112x
HR 192x
HR 113x
HR 193x
(914 mm)
HR 195x
(1219 mm)
68
Width
X
30"
3 13/16"
(97 mm)
36"
3 13/16"
(97 mm)
48"
3 1/4"
(82 mm)
Installing the range with the
anti-tip device
Wear safety shoes and gloves.
The anti-tip device should be installed
at the bottom rear of the range at the
midpoint of the width.
Measure the installation space for the
range close to floor level.
Mark the wall at the middle of the
space width.
Position the notch of the anti-tip
bracket on the wall marking.
The anti-tip device must fit tightly on
the floor or the wall.