Telescopic Rail Variant - Fujitsu FibreCAT TXF Operating Manual

Backup subsystem
Table of Contents

Advertisement

Installation
Installation in the PRIMECENTER Rack or DataCenter Rack
3.5.2

Telescopic rail variant

When mounting the left telescopic rail in the PRIMECENTER/DataCenter Rack,
the supplied support bracket must first be mounted on the rear left support
upright flush with the bottom edge of the device.
2
1
Figure 10: Fitting the support bracket
Ê Position the support bracket at the corresponding height on the rear left
support upright, (insert lug in corresponding hole) (1).
Ê Secure the bracket with two screws incl. plug washers (2).
2
1
Figure 11: Removing the carrier rail
Ê Extend the telescopic rail fully (1).
Ê Press the locking lever to release the carrier rail (2).
Ê Remove the carrier rail.
Ê Repeat the last three steps with the second telescopic rail.
Operating Manual
29
FibreCAT TXF