1.
Specify the LPI sampling interval, which determines the interval at which EEE LPI data
needs to be collected. the default value is 3600, and the range is 30 to 36000.
2.
Specify the maximum number of LPI samples to store on the switch. The default is 168, and
the range is 1 to 168.
3.
Click Apply to send the updated configuration to the switch. Configuration changes take
effect immediately.
4.
Click Refresh to refresh the page with the most current data from the switch.
Use the Interface menu to view LPI sampling information for that interface. The following
table shows the per-interface information:
Field
Sample No
Time Since The Sample
Was Recorded
Percentage Time spent in
LPI mode since last sample
Percentage Time spent in
LPI mode since last reset
GS748T Smart Switch
Description
Sample index.
Each time the page is refreshed it shows a different time as it reflects the
difference in current time and time at which the sample was recorded.
Percentage of time spent in LPI mode during the current measurement
interval.
Percentage of time spent in LPI mode since EEE LPI statistics were last
reset.
56