Battery Installation - Craftsman 82339 Owner's Manual

Digital multimeter
Table of Contents

Advertisement

SPECIFICATIONS
Operating Temperature
Storage Temperature
Relative Humidity
Operating Altitude
Operating Humidity
Weight
Size
Safety

BATTERY INSTALLATION

WARNING: To avoid electric shock, disconnect the test leads from any
source of voltage before removing the battery door.
1. Disconnect the test leads from the meter.
2. Open the battery door by lifting the rear stand and removing the two
screws using a Phillips head screwdriver.
3. Insert the battery into battery holder, observing the correct polarity.
4. Put the battery door back in place. Secure with the two screws.
WARNING: To avoid electric shock, do not operate the meter until the
battery door is in place and fastened securely.
NOTE: If your meter does not work properly, check the fuses and battery to
make sure that they are still good and that they are properly
inserted.
o
o
32
F to 104
F (0
o
o
10
F to 122
F (-10
<70% operating
2000 meters (7000ft.) maximum.
Max 70% up to 87ºF (31ºC) decreasing linearly
to 50% at 122ºF (50ºC)
12.34oz. (350g).
7.52" x 3.23" x 1.42" (191mm x 82mm x 36mm)
For indoor use and in accordance with
Overvoltage Category II, Pollution Degree 2.
Category II includes local level, appliance,
portable equipment, etc., with transient
overvoltages less than Overvoltage Category
III.
9
o
o
C to 40
C)
o
o
C to 50
C)

Advertisement

Table of Contents
loading

Table of Contents