Service error messages
Error code
846.06
846.07
847
847.01
847.02
848
848.01
849
849.01
9xx.xx service errors
900.xx Service
RIP Software
902.xx Service
Engine Software
903.xx Service
Engine Software
904.xx Service
Engine Software
905.xx Service
Engine Software
906.xx Service
Engine Software
Description
Front calibration strip has excessive
dark area.
Front magnification exceeds limits
Modem failure
Fax storage
Fax storage
Modem/Config ID mismatch
Modem/Config ID Mismatch
HD/Config ID mismatch
HD/Config ID mismatch.
Unrecoverable RIP software error/
illegal trap.
A general engine software error.
A general engine software error.
A general engine software error.
A general engine software error.
A general engine software error.
Action
Front excessive variability for Mono, Red,
Green, or Blue. Go to
"CCD service
check" on page
2-60.
Rear excessive variability for Mono, Red,
Green, or Blue. Go to
"CCD service
check" on page
2-60.
The Configuration ID bit that describes the
device's modem doesn't match the actual
modem installed in the device.
The amount of flash storage available on
the device is too small.
Note: The NAND Flash partition can shrink
as bit failures cause blocks to be
invalidated.
Go to
"Format Fax Storage" on
3-37. If the issue is not fixed, replace
page
the RIP board. Go to
"RIP board
removal" on page
4-19.
The devices' flash partition is invalid or
unavailable. Go to
"Format Fax Storage"
3-37. If the issue is not fixed,
on page
replace the RIP board. Go to
removal" on page
4-19.
A device doesn't have a modem installed,
even though its Configuration ID indicates
that a modem should be present.
A device has a modem installed, but its
Configuration ID indicates that a modem
shouldn't be present.
A device doesn't have a hard drive
installed, even though its Configuration ID
indicates that a hard drive should be
present.
A device has a hard drive installed, but its
Configuration ID indicates that a hard drive
shouldn't be present.
Go to
"900.xx system software error
service check" on page
2-28.
Go to
"90x.xx error (902.xx–907.xx)
service check" on page 2-31
Go to
"90x.xx error (902.xx–907.xx)
service check" on page 2-31
Go to
"90x.xx error (902.xx–907.xx)
service check" on page 2-31
Go to
"90x.xx error (902.xx–907.xx)
service check" on page 2-31
Go to
"90x.xx error (902.xx–907.xx)
service check" on page 2-31