8. Input / Output
The electrical diagram of i-Rec B104
<Note> Trimming wire
When connecting a wire to a terminal block, follow the instructions below. Note the different
types of wire that can be used.
30
(1) Compress the wire with the appointed
blade terminal. Use an insulator against
electric shock.
(2) Stranded Wire: Peel off the wiring
cover 8~10mm and solder it. Wire gage
should be AWG 18 ~ 28.
(3) Solid Wire: Peel off the wiring cover
8~10mm and solder it. Wire gage should
be AWG 16 ~ 28.