INSTRUCTION MANUAL PT6800 TRUNKING PORTABLE TRANSCEIVER We are very grateful for your purchasing brand transceivers produced by Kirisun Electronics (Shenzhen) Co., Ltd. We believe transceiver, which always incor- porates the latest technology, can bring great convenience to your life and work; we also believe that the quality and...
Page 3
Please don't put the transceiver in extremely dusty, moist or dabbling places; don't place it on unstable surfaces, either. If the transceiver emits smoke or strange odors, turn it off and remove the battery from the transceiver and promptly contact your local authorized KIRISUN dealer.
CONTENTS Making a Voice Call ( through Keypad Mainly ) Receiving a Voice Call UNPACKING AND CHECKING Cancel a Call Supplied Accessories Redialing 5 Digit Dialing PREPARATION Queue Incoming Call Battery Info Cancel Queue Incoming Call Battery Precautions Call Diversions Battery Care Tips Diverting Your Own Call Battery Recycling and Disposing...
Page 5
UNPACKING AND CHECKING Fast Searching in Contact List Manually Select Control Channel Unpack the transceiver carefully. We recommend that you Manually Select System Code to Join the Network identify the items listed in the following table before Keypad Lock & Rotary Encoder Lock discarding the packing material.
PREPARATION short-circuited, excessive current will flow and the battery Battery Info may generate heat or smoke, rupture, or burst into flame. It Battery Precautions will also cause metal object to heat up. CAUTION 3) Do not incinerate or apply heat the battery! 1) Do not recharge the battery pack if it is already fully If the insulator is melted, the gas release vent or safety charged.
Page 7
voltage or current over regulated value, or with a remodeled 13) Do not reverse-charge or reverse-connect the battery! charger), it may overcharge or an abnormal chemical The battery pack has positive and negative poles. If the reaction may occur. The battery may generate heat or battery pack does not smoothly connect with a charger or smoke, or burst into flame.
9) Please use KIRISUN charger to ensure battery normal work 1) Charge the new battery pack continuously for 4~7 hours and prolong its life. The battery and charger are designed before its initial using, which ensures the maximum battery under an integrated concept of power system.
Notes: Charger Indicator Status 1) The battery is not fully charged in the factory, and probably the new battery is falsely indicated as full charge. Before The battery is in the state of charging. the initial use, please charge the new battery continuously for 4~7 hours.
2) And then pull the battery away from the supplied screw. the transceiver. Notes: 1) Only use the KIRISUN Speaker/ Installing the Antenna Microphone. Screw the antenna into the con- 2) Two optional models are available: nector at the top of the transceiver...
B Antenna Scroll upwards to view the previous page. C Rotary Encoder Key: Down Key Rotate this knob to select your desired call address (voice Scroll downwards to view the next page. calls, dialing) or status (status calls) in TRUNKING mode, Key: Message Key to select your channel in CONVENTIONAL mode, or Press to view status messages or data messages.
TRUNKING MODE ICON DESCRIPTION Power ON/OFF 1) Turn the On-Off/Volume control knob clockwise to switch on Shows the strength of receiving signals. the transceiver. All characters on display flash and the power-on text message appears. The transceiver will Appears when a control channel is found. Flashes while automatically begin hunting for a control channel.
Page 13
Viewing message, one is for Sending unit and the other is for Viewing the Built-in Status Message Content . The Sending unit displays the sender's ID 1) If you have selected the function of viewing the built-in and the Content displays built-in status message.
unit Content . Viewing the Parameters d. There are up to 5 reveived received data messages can be 1) If you have selected the function of enable menu and the stored in memory. But all messages will be lost when the corresponding facilities by PC software, press key in transceiver is switched-off.
calls. 7) When SelSys displays, press to select the system j. Silence -- display and set the ON/OFF of the mute of manually. SelSys xxxx xxxxxxxxxxxx will be displayed. Beep and incoming calls. (The exact display lies with the setting of system.) k.
mode. code+ group call number + # /PTT 4) The ASCII name of a contact can also be displayed if it has Dialing sequence: 2+8+9+0+9+# /PTT been set. Group call of different prefix and fleet: Input prefix code + fleet code + group call number +# /PTT Dialing sequence: 2+0+1+2+8+9+0+9+# /PTT Radio Calls Making a Voice Call ( through Keypad Mainly )
After the call, LCD displays Call Ended , and then the party whose ID number is 237-2341-214, you can only transceiver returns to the Home address if you have preset it press 2 3 2 1 4+ / PTT button to call. by PC software, otherwise, resumes the caller's address 4) If make a group or individual call of a small fleet, you need to displayed before.
transceivers. a. Dial in the sequence of +4+4+ to divert all calls. 2) Make sure own call diversion function has been set by PC b. Dial in the sequence of +4+4+1+ to diverts voice calls software. only. 3) While in standby mode, you can divert the call through the c.
has been set by PC software) and Complete A status message code is a one used for transmitting SUCCESS appears on the screen. sending preset messages. 3) To cancel call diversion on other transceiver, follow the 2) Make sure status message call function has been set by operations below: PC software.
been set by PC software) and Complete set by PC software) and Call failed FAIL SUCCESS appears on the screen. Unavailable NO ANS appears on the screen. If the e. If the transmitting fails, warning tone sounds (if it has been input call address is invalid number, Null number set by PC software) and...
Priority Call Include Call 1) Priority Call allows you to have the priority over other users 1) Include Call allows the third party to join the talk in the cou- when requesting a call. rse of talking. 2) Make sure that priority call function has been set by PC 2) Make sure that...
5 ~9-digit dialing mode: Extension code composed of digits that Network Operator Service Call function has been 0, 7 or 8 should be added before the PABX extension set. number to dial. 3) Input the number of the dispatch station (see Appendix Press key or PTT button to call.
Special Features 2) Input the number you are searching and press key to Remote Kill & Reactivate fast switch to this number. The fast searching is only 1) The base station can give remote killing order to the lost or available for individual and group numbers.
selecting system code manually. PC software. By the way you preset you can enable or 2) Make sure that select system code manually functio has release the rotary encoder lock. been set by PC software. And the manually selecting has icon appears on the screen when the lock is active;...
set by PC software as switch between conventional mode Conventional Channels and trunking mode , you can enter conventional mode by 1) Press PTT to send transmit and release to receive. pressing 2) Through PC programming the parameters of conventional 4) The transceiver can be set to enter conventional channel mode can be set, such as channel name, RX/TX frequency automatically when missing the control channel.
Scan Pause channel. symbol appears on the screen. 3) Press Redial/Monitor button again to cancel monitor If the signal is detected while in channel scanning, the scanning will pause and the information of the paused function and resume the original state. channel will be displayed.
1) Time-out timer is to prevent any single person from using a Channel Lock channel to transmit for an extended period of time. 1) Make sure you have selected the Rotary Encoder Lock by 2) If you continuously transmit longer than the time limit preset PC software.
MPT1343 Dial Mode Function Dial string Cancel a call Dial digit Function Dial string Send status message Individual number 20~89 Send short data message 2 digits Group number 90~99 Conference calls Broadcast calls Individual number 200~899 Priority voice calls 1981# Group number 900~998 Emergency voice calls...
TROUBLESHOOTING SPECIFICATIONS PT6800-2 PT6800-4 Battery Standard DC 7.2V Case size(W H D) SOLUTION 56mm 120 mm 35 mm PROBLEM Weight 214g(Body)413g(with battery and antenna) Battery pack may not be installed properly. Remove the battery pack Receiver The radio cannot be and install it again.
Page 31
SOLUTION PROBLEM PROBLEM SOLUTION It's searching the network, and Please check if you have selected please make sure: Enter Conventional Mode Frequently switch Whether the starting channel of when the control channel cannot the network and the correspond- between trunking mode Hunting remains on be found or Trunking Search...
Need help?
Do you have a question about the PT6800 and is the answer not in the manual?