Martin PAR 2 RGBW Zoom User Manual page 6

Hide thumbs Also See for PAR 2 RGBW Zoom:
Table of Contents

Advertisement

Do not connect devices to power in a chain that will exceed
the electrical ratings of any cable or connector used in the
chain.
The supplied power input cable is rated 6 A and can safely
supply only one fixture with mains power. Do not connect any
device to the fixture's MAINS OUT connector when using this
cable. If you replace this cable and also use the replacement
cable to supply only one fixture with mains power, the
replacement cable must also be rated 6 A minimum, have
three conductors 18 AWG or 0.75 mm² minimum conductor
size, have an outer cable diameter of 6 - 15 mm (0.2 - 0.6 in.)
and be temperature-rated to suit the application. In the USA
and Canada the cable must be UL listed, type SJT or
equivalent. In the EU the cable must be type H05VV-F or
equivalent.
To connect fixtures to mains power in a chain, you must first
obtain 14 AWG or 1.5 mm
that are 16 A rated and temperature-rated to suit the
application. In the USA and Canada the cables must be UL-
listed, type SJT or equivalent. In the EU the cables must be
type H05VV-F or equivalent. Suitable cables with Neutrik
PowerCon connectors are available from Martin™ (see
'Accessories' on page 31). If you use these cables, you can
connect fixtures to power in a linked chain, MAINS OUT
throughput socket to MAINS IN input socket, but do not link
more than:
The voltage and frequency at the MAINS OUT socket are the
same as the voltage and frequency applied to the MAINS IN
socket. Only connect devices to the MAINS OUT socket that
accept this voltage and frequency.
Protection from burns and fire
Do not operate the fixture if the ambient temperature (T
exceeds 40° C (104° F).
The surface of the product casing can reach up to 85° C
(185° F) during operation. Avoid contact by persons and
materials. Allow the fixture to cool for at least 15 minutes
before handling.
6
eight (8) RUSH PAR 2 fixtures in total at 100-120 V, or
eighteen (18) RUSH PAR 2 fixtures in total at 200-240 V.
RUSH PAR 2 RGBW Zoom™ User Manual
2
power input and throughput cables
)
a

Advertisement

Table of Contents
loading

Table of Contents