Approximate Pressure Ranges
Depending on operating ambient and incoming
water temperature.
CUBERS
Freeze
Cycle
Suction
Head
Pressure
Start – End
Refrigerant
Pressure
R-12
125
20-12
R-22
225
35-22
R-502
225-250
30-18
FLAKERS
Refrigerant
Head Pressure
R-12
125
R-22
225
R-502
225
For Volts, Amps, Fuse Size and Refrigerant Charge see
Serial Nameplate.
Serial Name Plate Location.
1.
Electric box inside machine.
2.
Lower left side, Corner of cabinet.
Pressure Settings.
Crankcase pressure regulating valve factory setting with unit
in the Harvest Cycle:
R-22
45 lbs. maximum
R-502
50 lbs. maximum
Water cooled factory high side pressure settings with units in
the ice making mode.
R-12
120 lbs.
R-502
240 to 250 lbs.
R-22
200 lbs. for 300 and 322 Series
225 lbs. for 500 and 1400 Series
5
DFROST
CYCLE
Head
Suction
Pressure
Pressure
85-95
45
180-190
50
180-190
50
Suction Pressure
6-9
22-24
18-20
TD 184