THE FOLLOWING MAINTENANCE SHOULD
BE PERFORMED AT LEAST EVERY SIX
MONTHS ON FLAKED ICE MACHINES
1.
Check power supply with machine running for prop-
er voltage.
2.
Check water level in the float tank reservoir. Water
level should be maintained at the top of the evapo-
rator. Adjust if necessary.
3.
Clean the air-cooled condenser coil with a stiff
brush or vacuum cleaner.
CAUTION: CONDENSER COOLING FINS ARE
SHARP, USE CARE WHEN CLEANING.
4.
Clean the ice storage bin and flush the bin drain at
least once a month.
5.
If a water conditioner is installed in the inlet water
line, change, replace or clean the filter, strainer or
cartridge as required.
6.
If heavy mineral deposits on the auger and evapo-
rator shell are encountered due to bad local water
conditions, follow sanitizing and cleaning proce-
dure.
7.
Loosen hold–down cam locks and remove gear
motor assembly.
8.
Check thrust washer; replace if noticeably worn.
9.
Lift out auger and examine for wear. If the Helix
auger or the corkscrew auger round bar becomes
flat on the inside more than 1/8 of an inch over a
length of two inches or more it should be replaced.
NOTE: HELIX AUGERS DO HAVE MACHINED
FLAT RELIEF SURFACES. DON'T CONFUSE
THEM WITH WORN FLAT AREAS.
Check the insert in the bottom ring of the Helix au-
ger and replace if excessively worn.
10. Check shell vertical strips for wear. Replace the
shell if excessive wear shown.
11. Check O-ring, replace if worn or cut.