Temperature / Pressure Charts; Air Temperature; ± 10 Lbs. Discharge Pressure; Water Temperature - Cornelius IMD Series Installation Manual

Countertop icemaker imd series
Hide thumbs Also See for IMD Series:
Table of Contents

Advertisement

The operating positions of the switch are fixed, no adjustments are necessary. If switch replacement becomes
necessary, simply disconnect cable at connector, remove wires from switch.
IMD300- - 5 & IMD300- - 15
40_
50_
80
60_
92
70_
114
80_
124
90_
161
100_
187
NOTE: The thermostatic expansion valve is non- -adjustable on all models.

REFRIGERATION SYSTEM ADJUSTMENTS

A complete understanding of the icemaker and hermetic refrigeration system is necessary before any adjust-
ments are made. The refrigeration technician must use high and low side pressure readings, water and air tem-
peratures, plus general conditions of cleanliness to assess the refrigeration system status when making any
adjustments.
All icemaker products are tested and adjusted at the factory prior to shipment where the ambient temperature
ranges from 65_ F to 90_ F, depending on the season of the year.
Whenever a new icemaker is initially installed and started--up, it is imperative that the start--up operator make
the following checks and readjustments for local conditions.

EXPANSION VALVE

You will find a thermal expansion valve on ice makers, which is used to control the amount of refrigerant flowing
through the evaporator. Improperly installed or defective expansion valves may cause low production, soft ice,
squeaking from evaporator and excessive load inside evaporator.
By using general refrigeration trouble shooting along with the pressure charts, you can easily determine whether
or not the expansion valve is working properly.

ADJUSTMENT AND TROUBLESHOOTING

When troubleshooting the expansion valve, you must;
1. Be sure you have adequate water flowing into the evaporator, a clean and properly ventilated condenser,
and the system is properly charged and free of any restrictions. Also be sure compressor is operating prop-
erly.
2. Take reservoir water temperature and air temperature from condenser inlet and determine at what pressure
unit should be running. On machines equipped with thermostatic valve there is NO adjustment. If correct
pressure cannot be obtained, be sure system has time to stabilize, 10--15 minutes.
3. Be sure sensing bulb is located at outlet side of evaporator about 3--4 inches away from evaporator and be
sure to insulate well and clamp tightly to tubing. If system pressures are still not adequate, take a second
water and air temperature reading and go over other parts of the system for possible problems. If proper
charge is questionable evacuate and recharge to nameplate and leak check. If valve still malfunctions re-
place valve.
638085277

TEMPERATURE / PRESSURE CHARTS*

± 10 lbs. Discharge Pressure

Water Temperature

IMD300- - 30
65_
90_
40_
162
85
90
188
97
102
214
120
124
245
120
147
275
167
171
309
193
195
IMD600- - 30, IMD600- - 90
65_
90_
166
168
174
192
194
202
218
220
230
249
251
265
279
281
300
313
315
328
12
40_
65_
90_
177
180
205
208
233
236
272
269
307
304
334
340