Gas Installation; Combustion And Ventilation Air - Napoleon Tourch GSST8N Installation And Operating Instructions Manual

Table of Contents

Advertisement

3.2

GAS INSTALLATION

ALL GAS CONNECTIONS MUST BE CONTAINED WITHIN THE APPLIANCE WHEN COMPLETE.
The appliance is designed to accept a 1/2" gas
3.2.1
supply line. The appliance is equipped with a 1/2"
manual shut-off valve.
The access to the gas inlet is located in the bottom
3.2.2
of the cabinet.
The shut off valve / fl ex connector assembly must
3.2.3
always be contained within the cabinet.
When fl exing any gas line, support the gas valve
3.2.4
so that the lines are not kinked.
Check for gas leaks by brushing on a soap and
3.2.5
water solution.
3.3

COMBUSTION AND VENTILATION AIR

This appliance is intended for installation on an outdoor patio or in your yard. It must never be installed inside
the warm air envelope of your structure.
It is highly recommended that this appliance be installed in a "sheltered" area. Direct wind will cause an erratic
fl ame and possible pilot or main burner outage. An erratic fl ame could also lead to excessive carboning (black
soot), this condition is not a safety issue but is visually undesirable.
Typical installation may include covered patio, screened porch, gazebo, or on an outside wall of a house.
WARNING
!
DO NOT USE OPEN FLAME.
WARNING
!
ENSURE THE AREA HAS ADEQUATE VENTILATION.
W385-0380
FLEX
CONNECTOR
SHUT OFF
VALVE
W415-0689 / A / 06.08.10
9