General Information - Napoleon Tourch GSST8N Installation And Operating Instructions Manual

Table of Contents

Advertisement

6
THIS GAS APPLIANCE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to
conform with local codes. Installation practices vary from region to region and it is important to know the
specifi cs that apply to your area, for example in Massachusetts State:
The appliance damper must be removed or welded in the open position prior to installation of a appliance
insert or gas log.
The appliance off valve must be a "T" handle gas cock.
The fl exible connector must not be longer than 36 inches.
A Carbon Monoxide detector is required in all rooms containing gas fi red appliances.
The appliance is not approved for installation in a bedroom or bathroom unless the unit is a direct vent
sealed combustion product.
The installation must conform with local codes or, in
absence of local codes, the National Gas and Propane
Installation Code CSA B149.1 in Canada, or the National
Fuel Gas Code, ANSI Z223.1 / NFPA 54 in the United
States. Suitable for mobile home installation if installed in
accordance with the current standard CAN/CSA Z240MH
Series, for gas equipped mobile homes, in Canada or
ANSI Z223.1 and NFPA 54 in the United States.
2.3

GENERAL INFORMATION

FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ENSURE ITS OPERATION
AND QUALITY!
Altitude
Maximum Input
Minimum Inlet Gas Supply Pressure
Maximum Inlet Gas Supply Pressure
Manifold Pressure Under Flow Conditions
When the appliance is installed at elevations above 4,500ft, and in the absence of specifi c recommendations
from the local authority having jurisdiction, the certifi ed high altitude input rating shall be reduced at the rate of
4% for each additional 1,000ft.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convert-
ible for use with other gases, unless a certifi ed kit is used.
Expansion / contraction noises during heating up and cooling down cycles are normal and are to be expected.
Purge all gas lines with the glass door of the appliance removed. Ensure that a continuous gas fl ow is at the
burner before replacing the door.
Objects placed in front of the appliance must be kept a minimum of 48" from the front face of the unit.
Use only authorized accessories designed for and listed with the model.
W415-0689 / A / 06.08.10
www.nficertified.org
RATES AND EFFICIENCIES
NATURAL GAS
4.5" Water Column
7" Water Column
3.5" Water Column
We suggest that our gas
hearth products be installed
and serviced by professionals
who are certified in the U.S.
by the National Fireplace
Institute ® (NFI) as NFI Gas
Specialists
4.3
0 - 4,500*
6,000
PROPANE GAS
0 - 4,500*
6,000
11" Water Column
13" Water Column
10" Water Column