The operations and maintenance of your PelPro SERIES biomass appliance are unique and should not
be considered to be like a wood, coal, gas, electric, propane or oil heater, stove or appliance.
Cautions
:
Do not try to operate your stove with viewing door open. Pellets will not feed under these
circumstances and a safety concern may arise from sparks or fumes entering room.
If you are not drawing combustion air from outside, care must be taken to allow for adequate air
make up, to avoid possible room air starvation when stove or other exhaust fans are in
operation.
It is highly recommended that you install a high quality smoke detector as well as a carbon
monoxide gas detector in the room where stove is installed. Care should be taken to make
sure detectors are in working order at all times.
FUEL CONSIDERATIONS
Series Multi-fuel appliance
Your PelPro
1.
Wood pellets that comply with the Pellet Fuel Industries standards.
2.
Shelled corn
3.
Wheat.
4.
Or a combination of the above.
Fuel in the form of wood pellets is stored in the hopper. An auger delivers the pellets to
the burn grate. The fuel rate, or heat output, is set by adjusting the feed rate touch pad,
(settings 1 to 4). A fan provides combustion air to the burn grate. The amount of com-
Memory &
bustion air in the burn grate is adjustable and automatically changes as the fuel rate
Fan Trim
changes. The higher the fuel rate, the larger the amount of combustion air and visa
versa. The fuel burns in the burn grate, producing heat. Some heat radiates out the
front of your stove. The majority of the heat passes around the heat exchange tubes
and air plenum around the firebox and is then moved into the room by the room air fan.
A small amount of heat must pass out the exhaust of your stove, along with gases, into
the atmosphere.
Your stove's heat output can be adjusted from setting 1-4, through the FEED RATE
touch pad, to vary your heat output from Low to High. The room air fan can be manually
adjusted through the FAN SPEED to run faster or slower to correspond to the amount of
as desired
as desired
heat being produced. The room air fan is also on a limit switch, controlled to run on high
when the stove reaches higher temperatures and then resume the speed you had se-
lected once it cools to a lower temperature.
Your stove can run efficiently over extended periods of time and at different heat output levels as long as the
fuel supply is uninterrupted and timely cleaning and maintenance is per-formed. An example of how im-
proper cleaning effects operations is; the exhaust pressure switch will shut the pellet supply off and your stove
will shut off if the exhaust system becomes
plugged.
PelPro Appliances
H
Y
A
H
Y
A
OW
OUR
PPLIANCE
OW
OUR
PPLIANCE
is designed to burn the following:
Solid Heat
Exchange
Solid 1pc
Door
Locking
Door Latch
Multi-Fuel
Burn Grate
www.pelprostoves.com
W
101
W
101
ORKS
ORKS
Ash Pit
50 lb.
Hopper
Removable
Auger Cover
Auger Motor
& Shaft
3‖ Dia. Exhaust
Fan Forced
2‖ Air Intake
Heating Fan