24-Hour Gear; Program Wheel; Meter Assembly - Aquathin ASC25K/F Getting Started

Soft & clean system
Table of Contents

Advertisement

The backwash cycle allows for the elimination of water
through the drain.
The brine rinse cycle gets rid of the salt water, while the
slow rinse cycle allows water to resettle. During these
cycles, no water flows through the system.
During the brine tank refill position, the filter is back in
service.

24-Hour Gear

The 24-Hour Gear enables the system to monitor water
usage and regeneration cycles. In order to set the current
time, press the Red time set button, and then rotate the
gear till it reads the same time of day as your local time.
The

Program Wheel

The program wheel works in cohesion with the 24-hour
gear to monitor water usage and regeneration cycles. A
simple method of setting the program wheel for typical
residential applications is to align the black arrow, white
dot and the gallons capacity (which can be calculated as
explained on
page
20).

Meter Assembly

The meter assembly of the SOFT & CLEAN water condi-
tioning system is simple and dependable as it mechani-
cally monitors water usage even during power failure and
initiates regeneration only when needed.
To ensure strength and durability, the meter assembly is
molded from glass-reinforced Noryl®.
22
© 2007-2013 Aquathin Corporation. All rights reserved.

Advertisement

Table of Contents
loading

Related Products for Aquathin ASC25K/F

This manual is also suitable for:

Asc40k/fAsc45k/fAsc60k/f

Table of Contents