Servicing Notes
Servicing should be carried out annually by a competent person such as a
CORGI registered engineer. It is a condition of Flavel Fires 2 year guarantee
scheme that this is carried out by a competent person i.e a CORGI
registered Engineer in accordance with these servicing notes.
The condition of the ceramic coal forms should be checked and if necessary
the whole set should be replaced with a genuine replacement set.
After any servicing work a gas tightness check must always be
carried out.
4.1
Removing the Burner Assembly from the fire.
4.1.1
Isolate the gas supply.
4.1.2
Remove fender from the front of the fire, as described in section 3.3 on
page 17
4.1.3
Remove the glass frame assembly from the fire, as shown in section
2.8 on page 13.
4.1.4
Remove the ceramic coal forms from the combustion chamber
taking care not to damage them.
4.1.5
Remove the two M4 burner retaining screws, located at the front of
each end of the burner.
4.1.6
Slide the burner off the rear injector and remove from the product.
4.2
Removing the Control Valve from the fire.
4.2.1
Isolate the gas supply.
4.2.1
Remove the fender as described in section 3.3, on page 17
4.2.2
Disconnect the pipe to the bulkhead fitting on the valve and disconnect
the pipe on the valve which runs to the inlet elbow.
4.2.3
Loosen the pilot pipe, disconnect the ignition lead from the electrode
and disconnect the thermocouple from the pilot assembly.
4.2.5
Remove the 2 off fixing screws which hold the valve mounting plate to
its mounting bracket and lift the valve and its mounting plate away from
the combustion chamber.
SECTION 4

MAINTENANCE

19