e)
To adjust the heat input via the touch control :-
Press the "up" button to light the main burner and adjust the heat input
to the maximum setting. (5.45kW heat input). Press the "down"
button to reduce the heat input to the minimum setting (2.05kW heat
input). If the low button is pressed and held continuously, the fire
will go pass the minimum setting and extinguish the flames
completely. See Fig. 15 below.
Fig. 15
"Up" button to increase heat
input
"Down" button to decrease
heat input or turn off main
burner
NOTE :
The touch control does not light the pilot, it only lights
the main burner when the pilot flame is established and regulates
the heat input between high and low.
f)
Check that the gas pressure is 20.0 mbar (+/- 1.0mbar) 8.0 in w.g.(+/-
0.4 in w.g.) with the main burner operating on "high".
To turn off the main burner :-
g)
Turn right hand control knob clockwise to the position marked
or press the down button on the remote handset until the flame
extinguishes, at this point a clicking noise will be heard from the motor.
To turn off the pilot flame :-
h)
Turn left hand control knob clockwise to the position marked
and the pilot flame will extinguish.
i)
After ensuring that the fire is safe to use it should be left on high
position to fully warm up. During this time a slight odour may be
noticed, this is due to the "newness" of the fire and will soon disappear.