Location - Nordyne M3RL 060A AW Installation Instructions Manual

Direct vent (sealed combustion) forced air gas furnaces bw series;, bwt series
Hide thumbs Also See for M3RL 060A AW:
Table of Contents

Advertisement

MANUFACTURER REQUIREMENTS-
GASEQUIPMENT VENTINGSYSTEM
NOT PROVIDED.
When the manufacturer
of a Product Approved
side
wall
horizontally
vented
gas
fueled
equipment
does
not
provide
the parts
for
venting
the flue gases,
but identifies"
special
venting
systems",
the following
requirements
shall
be satisfied
by the manufacturer:
1.
The
reference
"special
venting
system"
instructions
shall
be
included
with
the
appliance
or
equipment
instructions;
and
2.
The "special
venting
systems"
shall
be Product
Approved
by the board,
and the instructions
for that system
shall include
a part list and detailed
installation
instructions.
A copy
of all installation
instructions
for all
Product Approved
side wall horizontally
vented
gas fueled
equipment,
all venting
instructions,
all parts lists for venting instructions,
and/or all
venting
design
instructions
shall remain
with
the appliance
or equipment
at the completion
of the installation.
A Single trunk duct
,
D
_" Dual trunk duct
B w/crossover
connector
I
Transition
duct
C [p
w/branches
[']____[1_
7
II
II
II
Figure
2. Non-Platinum
Supply
Duct System
LOCATION
The furnace must be installed on a level sur-
face, and as close to the center of the air
distribution
system as possible. See Figure 1
for overall dimensions to determine the required
clearances
in hallways,
doorways,
stairs, etc.
to allow the furnace to be moved to the instal=
lation point. The furnace must be installed so
that all electrical
components
are protected
from water.
Minimum clearances
to combustible
materials
are listed in Table 4. Access for positioning and
servicing must be considered when locating the
unit.
This furnace is certified for use on wood floor=
ing. The furnace must be installed on a solid
surface
and must be level front-to-back
and
I
I
Top View
of Duct
Connector
Figure
4. Connector
Dimensions
Use Duct Connector
If "X" (Floor Cavity) is:
Model Part Number:
English
Metric (mm) Finger Tab Screw Dowr
7/8"
22
901987
904008
2"
51
901988
904009
4 1/4"
108
901989
904010
6 1/4"
150
901990
904011
8 1/4"
210
901991
904012
10 1/4"
260
901992
904013
12 1/4"
311
901993
904014
Table 5. Duct Connector
Sizes
FLOOR CAVITY
(depth equal to "X" in Table 5)
Figure 3. Floor Cavity
8