Nordyne M3RL 060A AW Installation Instructions Manual page 19

Direct vent (sealed combustion) forced air gas furnaces bw series;, bwt series
Hide thumbs Also See for M3RL 060A AW:
Table of Contents

Advertisement

Vent C onfiguration to
Provide 1 2"
Minimum
height above _
Snow Level.
12" Min.
19" Max.
Support
Outside
_
"
__
Wail
' '_
1,,2"
:__ insulation ol
__
_
Equivalent
red),
12"Above
Normally
Expected
Snow
Level
Figure
18.
Alternate
Horizontal
Vent
Installation
Exhaust
Vent
Option
B
Mounting
FacepIate Secured
Combustion
Air Inlet
Exhaust Vent
Option
C
Exhaust Vent
ion A
Grade
Level
jJ
12"
Min,
to
_fJ
Normal Snow Level
,o,o,
Figure
19.
Exhaust
and Combustion
Air
Pipe Clearances
the couplings, and the gasket is retained against
the wall by the outer face plate.
Face plates
must be fastened to the wall and the outside one
must be flashed as appropriate
to prevent entry
of water.
When the above kits are not used the following
steps are required:
1.
Check the hole size cut through the exte-
rior wall. Insure that the hole diameter is
less than the diameter of the couplings to
be used.
2.
Extend
the vent pipe through
the wall
approximately
1" and seal the area be-
tween the wall and pipe.
3.
Apply couplings
to the vent pipe on the
interior
and exterior
sides of the wall to
insure the pipe can not be pushed or pulled
through the wall.
4.
Insure the combustion air inlet pipe has a 90
degree termination
elbow, and is pointing
downward as shown in Figures 19 & 20.
Note that a combustion
air intake must be
provided with an elbow opening downward.
When the vent pipe must exit an exterior wall
close to the grade or expected
snow level, a
riser should be provided as shown in Figure 18.
Insulation is required to prevent freezing of this
section of pipe.
Vertical
Venting
For vertical
venting,
either
the configuration
shown
in Figure 20 or the Concentric
Vent
Termination
Kit may be used. Vertical venting is
one of the shortest
routing
methods
when
A= 12" Above Roof or
5-Min.
36" Max.
Snow Accumulation Level
Elbow
.... Exhaust
Plumbing
Vent
Roof Boot
(Typ. Both Pipes)
Note: If terminations
meet=
ing these vertical
require-
ments exceed the maximum
height for safe transit, the
vent and combustion
air in-
takes may be shipped with
the home for assembly
on
site. The furnace
must be
labeled to notify the installer/
user not to use the furnace
until the vent and combus-
tion air intake terminations
are installed.
Figure
20.
Vertical
Vent Termination
19