air limit switchopens.Removethe close-off
plate immediately afterthesupply air limit s witch
opens.Ifthefurnace operates formorethanfive
minutes with no returnair, setthe thermostat
belowroomtemperature, shutoff thepowerto
the furnace,and replacethe supplyair limit
switch.
DESCRIPTION
OF COMPONENTS
Figure 29 shows the location of each of the
functional components
described below. If any
component
of the furnace must be replaced,
use only factory authorized
replacement
parts.
Contact
your distributor
for the approved
re-
placement
parts.
Flame Sensor
- The flame sensor
acts to
prove that flame
has carried
over from the
ignitor to the opposite end burner. If no flame is
sensed, the furnace will be shut down automati-
cally.
Gas Valve = The gas valve controls the flow of
gas to the burners.
When the gas valve is
energized it automatically
opens and regulates
the gas pressure in the manifold.
Pressure
Switch
= The pressure switch veri-
fies that the inducer is drawing the combustion
gases through the heat exchanger. It also senses
a blocked condensate
drain condition.
Deck Limit Switch
(Auxiliary
Limit) - The
deck limit protects the furnace filter tempera-
ture from overheating
when
the motor has
malfunctioned.
If the deck switch opens, the
power for the furnace will shut down (see Figure
29).
Supply
Air Limit Switch = The supply air limit
switch prevents the air temperature
leaving the
furnace from exceeding the maximum outlet air
temperature.
Vent Safety
Switch
- The vent safety switch
shuts the furnace down if the outlet flue gas
temperature
increases
above
145°F.
This
switch protects the plastic flue system and the
inducer from over-temperature
conditions.
Flame Roll-Out
Switch
- This switch
pro-
vides flame roll=out protection
to the furnace
and combustion
air inlet pipe.
MAINTENANCE
It is recommended
that the furnace be checked
yearly. At a minimum, this check should include
the following items:
z: WARNING:
To avoid electricshock,
personal injury,
or death,
turn
off the
power
at the
disconnect
or the main service
panel
before
performing
any maintenance.
z WARNING:
Holes in the vent pipe or heat exchanger
can cause products
of combustion
to
enter the occupied
space.
Replace the
vent pipe or heat exchanger
if leaks are
found.
Failure to prevent
products
of
combustion
from being circulated
into
the occupied
space can crate poten-
tially hazardous
conditions,
including
carbon monoxide
poisoning,
that could
result in personal
injury or death.
Combustion
Air and Vent
System
Check
the combustion
air and vent pipe to
ensure
that it is not damaged,
corroded
or
blocked by debris. Any damaged
section
of
vent pipe must be replaced, and any obstruc-
tion or blockage
must be removed
prior to
operating
the furnace.
Air Filter
An air filter is supplied
with the furnace
as
shipped
from the factory.
Filters should be
changed or cleaned monthly during the heating
season. New or newly renovated
homes may
require more frequent changing
until the con-
struction dust has been removed.
/ WARNING'.
Never operate
the furnace
without
a
filter in place, Dust and lint in the return
air can build
up on internal
compo-
nents,
resulting
in loss of efficiency,
equipment
damage, and possible
fire,
29