Furnace Fails To Operate - Nordyne M3RL 060A AW Installation Instructions Manual

Direct vent (sealed combustion) forced air gas furnaces bw series;, bwt series
Hide thumbs Also See for M3RL 060A AW:
Table of Contents

Advertisement

call for heat until ignitionfailure occurs.
Uponignitionfailure,the warm-upis in-
creasedby 3-seconds on the nexttry. If
successful, t he timing remainsfixed at
this level. In general,wheneverignition
failure occurs the warm-up interval is
increasedby 3-seconds on the next try.
And if successful, i t remains there.Mini-
mumand maximum warm-uptime limits
are set at 6 and 54-seconds,respec-
tively.
7. Thefurnacecontrolmustproveflamevia
theflamesensor5 seconds afterthe gas
valveopens.If flameis sensed,all burn-
ers are on andthe ignitorcoolsoff. If no
flame is sensed,the gas valve closes
immediately a ndthe inducercontinues to
run. A secondtrial for ignition(step 6)
beginsif no flameis sensed.On the fifth
tryforignition, t hefurnace control i slocked
out and the red LED will blink 4 times
repetitively. The thermostat must be
openedfor at leastten secondsto reset
the furnacecontrolaftera lockout.Oth-
erwise,the furnacewill attemptanother
ignitionsequence in 1 hour.
8. The furnace control energizesthe cir-
culatingair bloweron the heatingspeed
30 secondsafterthe gasvalvecircuitis
energized
.
9. When the thermostat
has been satisfied,
gas valve
is de-energized.
10. The inducer
is de-energized
after a 30-
second
postpurge.
11. The furnace control keeps the circulating
air blower
energized
for
120 seconds
(factory
set) or 60, 90, or 180 seconds
(field adjustable).
(See Figure 27.)
12. Abnormal conditions: If a limit opens during
operation,
the inducer and circulating
air
blower continue to operate. The gas valve
is de-energized
immediately.
The blowers
continue to operate until the limit closes.
When the limit closes the inducer blower is
de-energized
immediately.
The circulating
air blower continues to operate for the speci-
fied delay (factory set at 120 seconds).
Cooling Mode:
1.
On a call for cooling the thermostat
closes,
applying 24 VAC to the G and Y terminals
on the furnace
control.
This closes
the
compressor contactor.
2.
The furnace
control energizes
the circu-
lating blower
(115 VAC) on the cooling
speed.
3.
When the thermostat
is satisfied,
the G
and Y terminals
on the control board are
de-energized
opening
the compressor
contactor.
4.
The circulating
air blower
is de-energized
after a 90-second
delay.
Fan Mode:
1.
On a call for fan operation, the thermostat
applies 24 VAC to the G terminal
on the
furnace
control
board.
2.
The
circulating
air blower
is energized
immediately
on the heating
speed.
3.
If the furnace
is operated
in the continu-
ous ON position at the thermostat
and is
then switched
to AUTO,
the circulating
blower will operate for a specified
delay
(factory set at 120 seconds).
Furnace
Fails to Operate
If the furnace
does not operate check the
following:
1.
Is the thermostat
operating
properly?
2.
Is the front door in place?
3.
Is the furnace
disconnect
closed?
4.
Has the circuit
breaker
tripped
or the
control board
fuse burned open?
5.
Is the gas turned on?
6.
Are any manual reset switches
open?
7.
Is the filter dirty or plugged?
8.
Is the flame
sensor
coated?
(Remove
and clean with emery cloth.)
9.
Is the deck switch open?
If the furnace
locks out after 5 attempts
for
ignition, it will try again every hour if a call for
heat remains. If the inducer and circulating
air
blowers are operating,
and items 1 through 8
have been checked,
press the red reset but-
ton on the vent safety switch. (See Figure 29.)
If the furnace
operates
after depressing
the
reset button, contact a qualified
service tech-
nician to identify and repair the problem.
If furnace still fails to operate, depress the red
reset buttons on the flame roll-out switch.
If the
furnace
operates
after depressing
the reset
button, contact a qualified
service technician
to identify and repair the problem.
31