Note: The size of the new orifices that will be
installed into the unit will depend upon the
type of conversion
(sea level or high alti=
tude; natural
gas or LP gas).
Honeywell
II_1__
Valve
OTHER
SIDE
PRESSURE
OF
CAP
REGULATOR
Figure 23. Convertible
Pressure
Regulator
Cap
Figure 24. Burner
Inspection
Burner
Orifices
\
Gas
Manifold
Flame
Observation
Burner
Box
Inlet
Access
Pressure
Cover
Tap
Inlet
Gas
Plate
Valve
Figure 25. Typical Installation
For Sealed
Burner
Box With Access Cover Plate
Converting
the Unit to Alternate
Gas
1.
Remove the orifice bag from the manifold
of the unit.
2.
Install the appropriate
gas burner orifices
into the gas manifold.
Remember
if in=
stalling at altitudes
above 4,000 feet to
install the proper orifices, shown in Table
12. When installing the new orifices, DO
NOT use pipe joint
compound
on the
orifice threads.
Screw the orifices into the
manifold
by hand until snug to eliminate
cross
threading,
then
tighten
with
a
wrench.
Before installing an orifice, check
the face or side of the orifice for the drill
number to ensure that it is the appropriate
size.
3.
For the conversion
to the alternate fuel,
the gas valve regulator cap must be turned
over, as shown
in Figure
23.
You will
unscrew the cap and reinstall for your in-
stallation. After reinstalling the cap, you will
be able to read "NAT" for the conversion
to
natural gas or "LP for the conversion
to LP
gas.
Reinstalling
the Burner
Assembly:
1.
Reinstall the gas manifold assembly to the
burner
box with the four
(4) fasteners,
which were removed
earlier.
2.
Carefully
reinstall the burner box into the
unit.
After installing
the burner,
inspect
the alignment of the burners with the heat
exchanger tubes.
The center of the burn-
ers should be aligned with the center of the
tubes.
3.
Reconnect the gas piping to the gas valve.
4.
Reconnect
the wires
to the gas valve
terminals.
5.
Reconnect
the rubber pressure
tubes to
the gas valve and the burner box.
Rein-
stall the burner access cover plate.
6.
Reconnect
the ignitor at the 2 position
plug.
7.
Reconnect
the flame sensor wire to the
burner box.
23