Duct Installation - Nordyne M3RL 060A AW Installation Instructions Manual

Direct vent (sealed combustion) forced air gas furnaces bw series;, bwt series
Hide thumbs Also See for M3RL 060A AW:
Table of Contents

Advertisement

DUCT INSTALLATION
Required floor, ceiling, and roof cut-out open-
ings must be carefully
located to avoid mis-
alignment
of the furnace (see Figures 6 & 7).
Installation procedures
are suggested
for typi-
cal furnace
installations
and need not be fol-
lowed in the exact listed sequence.
CUT OUT FLOOR OPENING
& FUEL LINE
HOLE
a. Determine
center of closet or alcove (Fig-
ures 7 & 8).
b. Locate
center of the floor opening,
mea-
sured 10" from the rear wall, and mark cut-
out measuring approximately
14-1/2" by 14-
1/2" (+ 1") for model duct connector
used
(refer to Figures 4 & 5).
c. Locate center of gas line hole, measured 23-
1/4" from the rear wall and 6-5/8" to the left of
center of the floor cut=out (See Figure 6) or
5-1/4" to the left of center of the floor cut-out,
or for entry through
right-side
of furnace
measured 9" to the right of center of the floor
cut-out.
d. Cut out floor opening and one gas line hole.
CUT DUCT OPENING (FINGERTABBED
ONLY)
a. Place duct connector through the floor open-
ing with bottom tabs resting on top of the
supply air duct.
b. Center duct connector and push back against
rear edge of floor opening.
c. Mark cut-out location (tab area) and remove
duct connector.
d. Cut out duct opening 1/16" larger than area
marked.
INSTALL
FURNACE
MOUNTING
PLATE
a. Place mounting
plate (supplied within duct
connector)
at rear of the floor opening (See
Figure 9).
12
TABS
TABS
111--.....
I/--.....
1. INSERT
DUCT PLENUM
CONNECTOR
INTO
DUCT CUT-OUT.
2. BEND BOTTOM
TABS
OVER
AND ONTO
THE UNDERNEATH
DUCT
SERVICE.
Figure
10. Installation
of Duct Connector
Duct Connector
t-_
t)
Duct
_
Narrow
Duct
Figure
11. Narrow
Duct Installation
STEP
1.
Fold Back Flap "B"
Cut- Out
Area "A"
Cut- Out
Area"A"
Top of Duct
Fold Back Flap "B"
STEP2.
Fold Back Flap"B"
Cut
"--_
Lines
"__lt
"B"'B"
_
Duct
Fold
Back Flap"B"
Bend
Duct
Connector
Tabs Up
and Over- (along length of duct)
/
\
Staple
Folded
Duct
Flap
(typ) to side of Duct
Connector
-k
Duct7
STEP 4.
Figure
12. Alternate
Installation