Nordyne M3RL 060A AW Installation Instructions Manual page 13

Direct vent (sealed combustion) forced air gas furnaces bw series;, bwt series
Hide thumbs Also See for M3RL 060A AW:
Table of Contents

Advertisement

SLIDE
FURNACE
ALL
THE
WAY
BACK
ONTO
MTG.
PLATE
/
Figure 13. "A", "B", & Platinum
Cabinet
Furnaces
SLIDE
FURNACE
ALL
THE
WAY
BACK
ONTO
MTG
PLATE
/
Figure 14. "A" Cabinet
Furnace on 911969
Coil Cabinet
(Non=Platinum
Series)
iNSTALLiNG
PLATINUM
SERIES
14"
ROUND
DUCT
CONNECTOR
a. Place duct connector through the floor open-
ing. (See Figure 9).
b. Secure duct connector
to floor.
iNSTALLiNG
SCREW
DOWN
DUCT CON=
NECTOR
a. Apply a bead of caulking,
mastic, or other
approved sealant around bottom side of 1/2"
flange and restrictor plate, when applicable.
b. Locate the duct connector
over duct and
carefully
lower screw down duct connector
into place.
c. Once duct connector
is located
on duct,
temporarily hold in place while fastening duct
connector to the floor using flat head screws
or nails. Be sure flanges of duct connector
stay in contact with the duct.
d. Screw plenum to duct making sure a seal is
made between the duct and the duct con-
nector. Additional
screws may be added if
required.
e. Cut away along edge of flange allowing the
center to drop into the duct. Remove section
of duct with caution, as edges will be sharp.
iNSTALLiNG
FINGER
TABBED
DUCT
CONNECTORS
a. Place duct connector through the floor open-
ing with bottom tabs extending
through the
duct opening. (See Figure 9)
b. Secure duct connector
to floor.
c. Bend bottom tabs under and up tightly against
the supply air duct. See Figure 10, page 12.
NOTE: The duct connector
is designed for use
on ducts 12" in width. When using the connec-
tor on 12" wide ducts, there may be insufficient
clearance to bend the tabs on two sides of the
duct connector.
In such cases the tabs may be
attached to the sides of the duct by using sheet
metal screws or other suitable fasteners.
(See
Figure 11).
If sealant, mastic, or tape is used to provide a
better seal, it should be approved by applicable
national or local codes.
ALTERNATE
ATTACHMENT
METHODS
This procedure
may also be used to install a
furnace
duct
connector
to narrow
metal
ductwork where insufficient clearance prevents
bending
of the duct connector
tabs at the
side(s) of the duct. See Figure 12, page 12.
1. Score and cut the top of the metal duct as
indicated in Step 1 or Step 2. With Step 1
choice, also cut out the metal from the shaded
area "A".
2. Fold the duct flap "B" up (Step 3, Figure 12).
3. At the front=to-back of duct run (Area "A"),
bend the duct tabs and secure them directly
to the duct.
4. At Area "B", bend the duct tabs up and back
over,
around
the
duct
connector,
(See
Step 3).
5. Fold/form the duct flap against the side of the
duct connector
and attach as shown, (See
Step 4). Use three (3) staples (minimum)
on
each duct flap OR, if a 2X block/joist
is not
provided,
use two (2) sheet metal screws
(minimum)
on each duct flap. An alternate
attachment
method is acceptable,
as long
as the plenum is securely attached.
6. Tape the duct flap edges with an approved
tape for a leak-free joint.
iNSTALL
FURNACE
a. Remove
furnace outer door(s) and bottom
fuel line knockout.
b. Place furnace onto duct connector
and cen-
ter with floor opening.
13