3.12

CONNECTION WITH OTHER DEVICES

(SUB INDICATOR OUTPUT AND SLAVE
INPUT)
The radar JMA-5200MK2 can be equipped with the following options:
x
Output for sub display unit (including operation analyzer)
x
When used as a sub display unit for other radar equipment
Use the following optional cables for the installation.
The option requires inter-connection cable CFQ5351 and inter-unit cable CFQ-5251.
Simplified inter-switch installation procedures.
(1) Remove the processing unit cabinet cover form the unit cabinet.
(2) Connect CFQ-5351 to the J5008 on the CBD-1702A.
(3) Attach 14 pin circular connector of the CFQ-5351 to the cabinet as shown above.
CFQ-5351
3-34
CFQ-5251