13
CENTRAL COMMAND CONTROLLER
Machine is not
picking up water.
Instruct customer on
how to operate their
machine
YES
Did this remedy
the problem?
13-10
MiniMAG – ALL
RECOVERY SYSTEM FLOW CHART
Verify customer
complaint
Retest the
machine
Empty tank and
clean "Drain
NO
Saver" and float
ball cage.
Turn on vacuum
NO
switch
GO to vacuum
Does the vacuum
motor diagnosis
motor run?
Verify Machine
operation
NO
1 of 3
Is there a
problem?
YES
Is the recovery
tank empty and the
"Drain Saver"
and float ball
cage clean?
YES
Are the gaskets
the clear recovery lid
and the stainless recovery
tank door in good
condition?
YES
Is the vacuum switch
turned on?
section
YES
Does the vacuum
motor run?
GOTO
PAGE 2
Instruct customer on
how to operate their
machine
Repair or replace
NO
parts as needed
Retest machine
Did this remedy
NO
the problem?
YES
Bill Customer
Mini-Mag Service Manual V1.0
Need help?
Do you have a question about the MINI-MAG SERIES and is the answer not in the manual?