13
CENTRAL COMMAND CONTROLLER
"DRIVE MOTOR" does
not work.
Replace the drive
assembly
Can you
rotate the drive
wheel by
hand?
Replace the drive
YES
motor
13-36
MiniMAG – TRACTION DRIVE w/CCII
DRIVE MOTOR DIAGNOSTICS
Operate machine
and verify the
customers
complaint.
Address machine
not turning on first.
Remove the drive
motor from the
drive assembly
Can you
rotate both drive
wheels forward by
Hand at the same
time?
Repair connection between
the controller output and the
drive motor.
1 of 1
Does the
drive motor work
properly?
NO
Does
anything else
NO
on the machine
work?
YES
Block the rear wheels of the machine
and raise the drive wheels off the floor.
Using a voltmeter set the meter to DC volts.
Connect the ( -) probe of the meter to the ( - )
drive motor terminal and the ( + ) probe of the
meter to the drive motor ( + ) terminal.
Depress the throttle pedal fully and read the
voltage.
Is the
motor receiving
YES
at least
10 volts?
NO
Using a voltmeter set the meter to DC volts.
On the controller back probe the (+) and (-)
traction motor wires. Depress the throttle
pedal fully and read the voltage.
Is there
at least 10
YES
volts at the
terminals?
NO
Replace controller
Instruct owner on
YES
proper machine
operation
Mini-Mag Service Manual V1.0