Cooling Fan Motor Malfunction; Dc Power Supply Fan Motor Malfunction - Konica Minolta bizhub C35 Service Manual

Hide thumbs Also See for bizhub C35:
Table of Contents

Advertisement

DRAFT
Field Service Ver. 1.0 Feb. 2010
14.4.5
004A: Cooling fan motor malfunction
Cooling fan motor (FM11)
Step
1
Check the connector between FM11-relay
CN29-PRCB PJ14 for proper connection
and correct as necessary.
2
Check the fan for possible overload and
correct as necessary.
3
FM11 operation check
4
Change FM11.
5
Change PRCB.
14.4.6
004E: DC power supply fan motor malfunction
DC power supply fan motor (FM10)
Step
1
Check the connector between FM10-relay
CN43-PRCB PJ14 for proper connection
and correct as necessary.
2
Check the fan for possible overload and
correct as necessary.
3
FM10 operation check
4
Change FM10.
5
Change PRCB.
Relevant electrical parts
Action
Relevant electrical parts
Action
14. MALFUNCTION CODE
Printer control board (PRCB)
WIRING DIAGRAM
Control signal
-
-
PRCB PJ14-4 (REM)
PRCB PJ14-6 (LOCK)
-
-
Printer control board (PRCB)
WIRING DIAGRAM
Control signal
-
-
PRCB PJ14-1 (REM)
PRCB PJ14-3 (LOCK)
-
-
Location (electri-
cal component)
-
-
G-15
-
-
Location (electri-
cal component)
-
-
G-15
-
-
209

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents