Follett Symphony 25CI400A Installation, Operation And Service Manual page 7

Ice and water dispensers
Hide thumbs Also See for Symphony 25CI400A:
Table of Contents

Advertisement

Fig. 4
4.1
4.2
4.4
4.3
Fig. 5
5.3
5.4
2. Disconnect the internal water line from the potable
water connection fi tting.
3. Remove fi tting from the back wall of the dispenser
(Fig. 4.1).
4. Relocate fi tting to internal bulkhead and reconnect
(Fig. 5.1).
6. Remove power cord strain relief (Fig. 4.2).
7. Relocate the cord and strain relief to the internal
bulkhead and reconnect (Fig. 5.2).
8. Water-cooled only. Disconnect internal condenser
water inlet and outlet fi ttings (Fig. 4.3).
9. Water-cooled only. Relocate water inlet and outlet
fi ttings and reconnect (Fig. 5.3). Note: The water
inlet is connected to the condenser; the outlet line is
connected to the water regulating valve.
10. Remove the drain plug from the internal drain line
connection point (Fig. 5.4).
11. Relocate to back of dispenser and reconnect
(Fig. 4.4).
25CI400A/W • 25HI400A • 50CI400A/W • 50HI400A
12. Raise the dispenser upright and position in desired
location.
13. Mark dispenser outline on counter and remove
dispenser.
Fig. 6
Countertop cutout viewed from top
1.56"
(40mm)
14"
(356mm)
14. Cut countertop utility opening and drill four 7/16"
holes to anchor dispenser to counter (Fig. 6).
15. Apply a thick bead approximately 1/4" (7mm)
diameter of NSF listed silicone sealant (Dow
Corning* RTV-732 or equivalent) 1/4" (7mm) inside
marked outline of dispenser.
16. Reposition dispenser on counter and secure to
5.2
counter with four 3/8"-16NC bolts.
17. Smooth excess sealant around outside of dispenser.
5.1
18. Make utility connections through countertop cutout.
• Do not connect water-cooled condenser outlet line to
the dispenser drain line.
19. Turn on water supply and check for leaks.
20. Clean and sanitize dispenser and ice machine
before putting into service.
21. Turn power on and allow icemaker to produce ice.
3.13"
16.00"
(80mm)
(407mm)
12.50"
Cutout
(318mm)
connections
through
bottom
.50"
20"
(13mm)
(508mm)
CAUTION
4X
Ø.375"
(10mm)
hole
7

Advertisement

Table of Contents
loading

Table of Contents