Loading the factory defaults can take up to 60 seconds to complete.
Loading defaults will only be possible if the NVM has not been
locked.
For a complete list of factory defaults, see the Premier Quick
Reference supplied on the enclosed CD.
12: Auxiliary Tamper/Fault Connections
These terminals can be used for monitoring the tamper loop of an
auxiliary device.
13: Loudspeaker Connections
These terminals can be used for connecting up to one 8Ω or two
16Ω loudspeakers.
14: Panel Outputs
Outputs 1 & 2 are 500mA '-ve'. These outputs are all fully
programmable.
Output 2 is not programmable on the 12-W & 24-W
15: Zone Connections
4 Fully programmable zone inputs
16: Ricochet Network LED's
Green LED = Data received by the expander from the panel Red LED
= Data transmitted by the expander to the panel. (The flash rate
depends on the mode and RF activity)
17: Enable 2 wire smoke (24/48-W Only)
Panel Output 1 can be used for connecting up to 10, 12V 2-Wire
smoke detectors.
18: Options Switch
Use to select the receiver functionality.
Switch 1 OFF =not used on Premier Elite 24/48-W.
Switch 2 OFF = Premier Elite 24/48-W Ricochet Mode
ON = Not Used
Switch 3 ON = Impaq Contact-W Wired Input 2 will report as Tamper
(default)
OFF = input 2 will report as an Alarm.
Switch 4 OFF Walk test
19: Ricochet Eng keypad connection
An engineer's keypad (Premier LCD keypad and interface lead) can
be temporarily plugged onto this connector to allow system
programming and testing. Set the keypad address switches to all
ON.
20: Ricochet Firmware Flash Port
Connections for flasher interface to update Ricochet receiver
firmware.( factory function only)
21: Commission Mode Jumper
Fit when learning and placing devices, remove once complete.
22: Antenna
RF antenna
23: RF LED's
Left = RED Transmit, Middle = GREEN Receive, Right = RED
Wireless Network Tick.
24: Plug-on Communicator Connections
This socket provides connection for Premier COM300/COM2400
plug-on communicators via the lead provided.
25: Ricochet Comm. Port Connection (24/48-W Only)
Serial communications port for connecting to a PC via PC Com/USB
Com or Com IP for use with Ricochet Monitor Software.
26: Cover Tamper
Provides tamper protection for the control panel.
27: Heartbeat LED/Power Light
Flashes steadily to indicate that the control panel is functioning
correctly. If the light is ON or OFF all the time, then there could be a
problem.
INS626
Premier Elite Ricochet Kits Quick Guide
28: Cover Tamper Disable
Disables the lid tamper
29: Flash Programming Port
For upgrading the panel firmware.
30: Battery Charge Selection(24/48-W Only)
Select .03A or 0.75A battery charging current
31: Current Reading Pads
To calculate the current draw of the control panel, measure the
voltage across the two pads and multiply by 10 i.e. Reading = 34mV
(x10) = 340mV = 340mA.
32: Battery Kick-start Button
When powering up the panel without AC Mains present, this button
must be pressed in order to connect the battery. If AC Mains is
present this button does not need to be pressed.
33: Power Supply Connection
Only for use with the Texecom PSU.
DO NOT CONNECT ANY OTHER MAINS SUPPLY TO THESE
TERMINALS
PTC Protection Fuses
The following fuses are provided:
F6 PTC (0.9A) Auxiliary 12V Power fuse
F4 PTC (0.9 A) Network 1 fuse
F5 PTC (0.9 A) Bell/Strobe fuse