Troubleshooting (continued)
Problem
"niGT on" is displayed.
"GAtE on" is displayed.
Compensation can not be
completed.
Measurement data not being
received at PLGR
VECTOR ™- USMC VECTOR 21-V.0.3
Possible cause
"niGT" is activated, for use with
a night vision device but used in
daylight conditions.
"DISt GAtE" is activated.
Timing out of compensation
(nothing in display).
Going too far on a command
Interface cable not properly
connected.
Combined measurement not
being used.
'PC Con' selected
www.
Shop for Vectronix products online at:
50
SCOUTBASECAMP
.com
1.877.766.5412
Solution
Select "niGT OFF" in the
configuration menu (see pages
28, 29).
Select an appropriate range
gate (see page 33).
Turn / tilt farther or move
faster.
Turn / tilt more slowly and stop
at the appropriate time.
Adjust cable connection.
Press range and azimuth
buttons simultaneously.
Change to 'PLGr Con'.
Troubleshooting