Icom IC-7400 Service Manual page 22

Hf/vhf all mode transceiver
Hide thumbs Also See for IC-7400:
Table of Contents

Advertisement

TRANSMITTER ADJUSTMENTS—continued
ADJUSTMENT
ADJUSTMENT CONDITION
HF BANDS
1
• Displayed freq. : 14.10000 MHz
OUTPUT
• Mode
• [RF POWER] : Max. CW
POWER
• [TUNER]
• Transmitting
50 M BAND
1
• Displayed freq. : 51.00000 MHz
OUTPUT
• Mode
• [RF POWER] : Max. CW
POWER
• [TUNER]
• Transmitting
1
• Displayed freq. : 145.00000 MHz
144 M BAND
OUTPUT
• Mode
POWER
• [RF POWER] : Max. CW
• [TUNER]
• Transmitting
1
• Displayed freq. : 14.10000 MHz
AM
CARRIER
• Mode
• [RF POWER] : Max. CW
• [MIC GAIN]
• Apply no audio signals to [MIC]
connector.
• Transmitting
AM
1
• Displayed freq. : 14.10000 MHz
MODULATION
• Mode
• [MIC GAIN]
• [RF POWER] : Max. CCW
• Connect an audio generator to
[MIC] connector and set as:
Frequency
Level
• Transmitting
FM
1
• Displayed freq. : 28.50000 MHz
• Mode
DEVIATION
• Tone
• [RF POWER] : Max. CW
• [MIC GAIN]
• Connect an audio generator to
[MIC] connector and set as:
Frequency
Level
• Transmitting
1
• Displayed freq. : 145.00000 MHz
RESIDUAL
AM
• Mode
• Tone
• [RF POWER] : Max. CW
• [MIC GAIN]
• Connect an audio generator to
[MIC] connector and set as:
Frequency
Level
• Transmitting
SWR
• Displayed freq. : 29.70000 MHz
DETECTOR
• Mode
• [RF POWER] : Max. CW
• [TUNER]
• Connect CP7 (SETI) on the CTRL
unit to GND.
• Connect a 50 Ω dummy load or an
RF power meter to [ANT1] connector.
• Transmitting
After adjustment, disconnect CP7 (CTRL unit) from GND.
MEASUREMENT
UNIT
Rear
: RTTY
panel
: OFF
Rear
: RTTY
panel
: OFF
Rear
: RTTY
panel
: OFF
Rear
: AM
panel
: Center
Rear
: AM
panel
: Center
: 1 kHz
: 10 mVrms
Rear
: FM
panel
: OFF
: Center
: 1 kHz
: 10 mVrms
Rear
: FM
panel
: OFF
: Center
: 1 kHz
: 4.5 kHz deviation
at the connected
deviation meter.
CTRL
: FM
: OFF (Through)
LOCATION
Connect
an
RF
power
meter
to
[ANT1] connector.
Connect
an
RF
power
meter
to
[ANT1] connector.
Connect
an
RF
power meter to [ANT
144MHz] connector.
Connect
an
RF
power meter to [ANT
144MHz] connector.
Connect a modulation
analyzer to [ANT1]
connector through an
attenuator.
Connect an FM devi-
ation meter to [ANT1]
connector through an
attenuator.
Connect an FM devi-
Minimum RESIDUAL
ation meter to [ANT
144MHz] connector
through an attenua-
tor.
Connect
a
digital
multimeter or oscillo-
scope to the check
point CP1.
5 - 6
ADJUSTMENT
POINT
VALUE
UNIT
100 W
MAIN
100 W
MAIN
100 W
MAIN
40 W
MAIN
100% or less
4.5 kHz ±0.3 kHz
RF
AM level
Minimum voltage
CTRL
ADJUST
R306
R311
R317
R320
Verify
Verify
L252,
L251,
C3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents