Timer Function; Turbo Function - Vivax ACP-07CIFM21GEI Service Manual

Table of Contents

Advertisement

When unit is running in cooling and dehumidifying mode, after sleep set up 1hr later, Tset will be increased 1
increased 2
, the Tset will not be exceeded 30
later, Tset will be declined 2

Timer function

The common setting for Timer:
a.Timer on: At unit off, can set up the Timer On function,when Timer On act, the controller will run at original setting mode, the Timer
interval is 0.5hr, setting range is 0.5-24hrs.
b.Timer off: At unit on, can set up the Timer Off function, when Timer Off act, the unit will turn off, the Timer interval is 0.5hr, setting range
is 0.5-24hrs.
Hours setting for Timer:
a. Timer on: If unit is running then to set up the Timer On, the unit will go on running, if the unit is off to set up the Timer On, when Timer On
act, the unit will run at the presetting modes.
b. Timer off: If unit is off then to set up the Timer Off, when setting the Timer off, the unit stand by, if unit is turned on to set up Timer Off,
when the Timer Off act, the system will stop to work.
c. Timer change: When unit is running in Timer mode, by operate the On/Off of remote controller to turn on or turn off the unit, can reset up
the Timer function, the unit will run at the mode of last setting.
If unit is running, at the same time to set up Timer On and Timer Off, the system will keep the present setting status, after the Timer Off
When system is running, at the same time to set up Timer On and Timer Off, the unit will keep the current presetting working status, if
Timer Off act, the unit will stop working.
When unit is stop running, at the same time to set up the Timer On and Timer Off, the unit will keep stop running, until Timer On act, the
unit will start to work, after this when Timer On of every day act, it will run at presetting modes, when Timer Off act, the unit will stop to work.
If the setting for the Timer Off and Timer On are the same, the Timer Off will act.
Memory function
Contents of memory: Modes, Up and Down Swing, Light, Setting Temp. Setting fan speed, Common setting for Timer (Hours will not
memorized). After Timer Off, when repower on, the unit will automatically turn on and run at memorized contents.
There is no Timer Setting in the remote control order that the unit will memorize the remote control order of last setting and it will run
at that mode.
There is common setting for Timer of last setting by remote controller, before the Timer act, if power off and after powered on, the unit will
memorize the timer of last setting by remote control, the timer will recalculate after powered on.
There is Timer function at last setting by remote control, if Timer function has act, the power off after Timer On or Timer Off, after powered
on, the unit will memorize the running mode before power off, under Hours setting for Timer, the memory is invalid.
I Feel function
When controller received the orders that the controller will work according to ambient temperature which is sent by remote control (Except
Defrost and Anti-cool wind, it will still adopt the air conditioner self ambient sensor sampling value), the remote control in every 10mins, to
sent the ambient temperature value to controller. 11mins later, the controller haven't received the ambient temperature value from the
remote control that the air conditioner will run itself ambient temperature. If there is no setting function that the ambient temperature will
adopt the AC sensor sampling value. Power off will not memorize this function.

TURBO function

Only in Cool or Heat mode, the Turbo setting is available, when controller received this order, the indoor fan will run at super high,
sent the outdoor unit Turbo signal and sent the high fan speed.
Up\Down swing fan function
After powered on, the up and down swing motor will firstly rotate the air guide board to postion O in anticlockwise, turn off the air vent. After
unit is turned on, if there is no swing function set up, under the Heat mode or Auto Heat mode, the up and down air guide board will rotate to
position D in clockwise; In other modes, the up and down guide board will roate to horizontal position L1 clockwise. When turning on the unit
to set up swing function synchronously. If unit is turned on to set up the swing function that the guide louver will swing between L and D.
There are 7 kinds of status of swing for guide louver: Position L, Position A, Position B, Position C, Position D, Position L and Position D,
Position L to Position D to stop swing ( the inclination between L-D is conformal). When unit is off the air guide louver will close and turn
to position 0. The swing is only valid while setting swing order and indoor fan motor is running.
Displayer
Basic display
; In heating mode, after sleep procedure set up 1hr later, Tset declined 1
; the Tset will not be exceed 16
, under Fan and Auto modes, the setting temperature will not be changed.
Heating angle
Artful Series
; 2hrs later, Tset will be
, 2hrs
Cooling angle
Angle
Angle