Sharp edges could cause injury, be especially careful of the case edges and the 1. Precaution fins on the condenser and evaporator. For installation, always contact the 1.1 Safety Precaution dealer or an authorized service center. Do not install the product on a ...
Page 4
There is risk of electric shock or fire. Keep level even when installing the Stop operation and close the window product. in storm or hurricane. If possible, remove It can avoid vibration of water leakage. the product from the window before the Do not install the product where the hurricane arrives.
Page 5
Do not drink the water drained from the product. Use a firm stool or ladder when cleaning or maintaining the product. Be careful and avoid personal injury. Replace the all batteries in the remote control with new ones of the same type.
2. Function Model Names of Indoor/Outdoor Units Capacity Indoor units ACP-07CIFM21AERI ACP-09CIFM25AERI ACP-12CIFM35AERI DC Inverter Multi Series ACP-18CIFM50AERI 2 ways of drainage Filter Cold catalyst filter Louver Position Memory Function Ionizer(O) Self-diag. Function Silver Ico Filter(O) ydrophilic Aluminum Fin Vitamin C Filter(O)
3. Dimension Model ACP-07CIFM21AERI ACP-09CIFM25AERI ACP-12CIFM35AERI ACP-18CIFM50AERI For ACP-07CIFM21AERI,ACP-09CIFM25AERI: For ACP-12CIFM35AERI,:...
Dispalys ‘ ’ during self clean operation (if 6. Electronic function aplicable). 6.1 Abbreviation Dispalys ‘ ’ under 8℃ heating operation (if T1: Indoor room temperature aplicable). T2: Coil temperature of evaporator T3: Coil temperature of condenser T4: Outdoor ambient temperature T5: Compressor discharge temperature 6.2 Display function 6.2.1 Icon explanation on indoor display board.
6.3 Main Protection 6.4.2.1 Compressor running rules The compressor will run at corresponding 6.3.1 Three minutes delay at restart for compressor frequency according to the gross amendatory 1 minute delay for the 1 time stand-up and 3 capacity demand. minutes delay for others. …...
Page 13
Cooling … Amenda … tory capacity demand. 6.4.3.2 Outdoor fan running rules Heating 6.4.2.3 Indoor fan running rules In cooling mode, indoor fan runs all the time and the speed can be selected as high, medium, low and auto. The indoor fan is controlled as below: Setting fan T1-Td ℃(°F) Actual fan speed...
Page 14
4-Way valve T1-Td -1.5 no longer than 10min -2.5 Compressor Cool-F9 (H+-L)*0.2+L -3.5 (H+-L)*0.4+L TimeA -4.5 10S 30S Indoor fan Anti cold wind (H+-L)*0.6+L -5.5 Outdoor fan (H+-L)*0.6+L -6.5 PMV running -7.5 (H+-L)*0.8+L 4 mins with 480P -8.5 480P 6.4.3.3 Defrosting mode If any one of the following items is satisfied, AC 6.4.4 Auto-mode will enter the defrosting mode.
Page 15
reaching the setting “on” time. Forced auto→Forced cooling→Off 6.4.7.6 The timer function will not change the AC current operation mode. Suppose AC is off now, it will not start up firstly after setting the “timer off” When the machine is off, pressing the touch button will carry the machine to forced auto function.
Page 16
the compressor will have 3 minutes delay when function will be turned off automatically, and the restarts. temperature will control the unit according to the room temperature detected from its own room 6.4.10 Louver Position Memory Function temperature sensor and setting temperature. When starting the unit again after shutting down, its louver will restore to the angle originally set 6.4.13 Mode conflict...