INSTALLATION INSTRUCTIONS
CHECKING THE GAS SUPPLY
1
Check the manometer zero point is correct.
2
Connect the manometer to the cooktop pressure point (located on the regulator).
3
Turn on the gas supply and electricity and try to ignite the gas burner.
Note: It will take additional time to light the gas for the first time as air needs to be purged from the pipes.
4
With the appliance operating check the outlet pressure
► When all burners of the appliance are operating at maximum,
► When the smallest burner of the appliance is operating at minimum.
▷ Under these conditions the outlet pressure should not vary from the nominal outlet pressure of
1.00kPa by more than ±0.20kPa.
If the regulator appears to not be performing satisfactorily, then check the following points:
1.
If the outlet pressure is consistently too low then the inlet pressure may be too low and adjustment of an upstream
regulator may be needed, or an upstream regulator or valve with insufficient flow capacity may be present in the gas
supply line. If this is suspected then it may be necessary to repeat the checks whilst measuring both the inlet and outlet
pressure to determine if the inlet pressure is in the range 1.13 – 5kPa.
2.
Check that the regulator has been fitted to the gas supply line in the correct orientation, the arrow on the base of the
body indicates the direction of gas flow.
Once these checks have been completed, if the regulator still fails to perform in a satisfactory manner it should be
replaced. Please contact the Residentia Support Team on 1300 11 4357.