Parameter
Output Programming Range
Typical Programming Resolution
Accuracy
( @ 25 °C ± 5 °C)
Drift Temperature Stability
(following a 30-minute warmup, change
in output over eight hours under constant
line, load, and ambient temperature)
Temperature Coefficients
(change per °C after 30-minute warmup)
Typical Common Mode Noise Current
(referenced to signal ground binding post)
Maximum Input VA and Power
AC Input Ranges
(selectable via internal switching
- see Appendix F)
Output Terminal Isolation
(maximum, from chassis ground)
Maximum AC Line Current Ratings
Maximum Reverse Bias Current:
Remote Sensing Capability
Load Regulation (∆mV)
94
Specifications
Table A-2. Supplemental Characteristics for Agilent E4356A
Overvoltage Protection:
Overvoltage Protection:
Overvoltage Protection (OVP):
Analog Programming (VP):
Analog Programming (IP):
Current Monitor (+IM):
Overvoltage Protection (OVP):
Analog Programming (VP):
Analog Programming (±IP):
Current Monitor (+IM):
1
Below 185 Vac, derate output voltage linearly to 75.3 V
With ac input power applied and the dc output reverse biased by an
external power supply, the unit will continuously withstand without
damage a current equal to its output current rating (see Table A-1).
Voltage Drop Per Lead:
Degradation due to load lead
Degradation due to load lead
Voltage:
Current:
Voltage:
Current:
Voltage:
Current:
Voltage:
Current:
Voltage Readback
±Current Readback:
rms
p-p
with full load:
with no load:
1
200 Vac
nominal:
230 Vac nominal:
Frequency:
200 Vac nominal:
230 Vac nominal:
Up to 1/2 of rated output voltage.
Load Voltage:
Subtract voltage drop in load leads
from specified output voltage rating.
∆mV = Vdrop(R
drop in – output:
∆mV = V
drop in + output:
2V
where
R
R
Value
81.9 V
30.71 A
96 V
20 mV
7.5 mA
150 mV
1.5 V
± 0.3%
± 7%
± 7%
0.02% + 2.5 mV
0.02% + 10 mA
50 ppm + 1.6 mV
75 ppm + 4 mA
60 ppm + 1.6 mV
85 ppm + 5 mA
200 ppm + 18 mV
60 ppm + 0.7 mV
275 ppm +5 mA
50 ppm + 0.6 mA
500 µA
4 mA
3800 VA; 2600 W,
100 W
174-220 Vac
191-250 Vac
47-63 Hz
±240 Vdc
19 A rms (25 A fuse)
19 A rms (25 A fuse)
– )/10
sense
(R
+)/10 +
drop
sense
(V
)/(V
+ 10V)
drop
rating
rating
– = resistance of – sense lead
sense
+ = resistance of + sense lead