Rst; Sav - Agilent Technologies E4356A Operating & Programming Manual

Telecommunications dc power supply
Table of Contents

Advertisement

*RST

Meaning and Type
Reset Device State
Description
This command resets the power supply to a factory-defined state as defined below. *RST also forces an ABORt command.
CAL:STAT OFF
CURR[:LEV][:IMM] *
CURR[:LEV]:TRIG *
CURR:PROT:STAT OFF
DIG:DATA 0
DISP[:WIND]:STAT ON
DISP[:WIND]:MODE NORM
DISP[:WIND]:TEXT
INIT:CONT OFF
* Model-dependent. See Table 7-1.
Related Commands

*SAV

Meaning and Type
SAVE Device State
Description
This command stores the present state of the power supply to the specified location in memory. Up to four states can be
stored. Under certain conditions (see "Turn-On Conditions" in "Chapter 5 - Front Panel Operation"), location 0 may hold
the device state that is automatically recalled at power turn-on.
The following power supply parameters are stored by *SAV:
CURR[:LEV][:IMM]
CURR:PROT:STAT
Related Commands
The power supply uses nonvolatile memory for recording register states. Programs that repeatedly use
*SAV for recalling states cause frequent write cycles to the memory and can eventually exceed the
maximum number of write cycles for the memory .
Command
Command Syntax
Parameters
Query Syntax
DIG:DATA[:VAL]
Command Syntax
Parameters
Example
Query Syntax
State
OUTP[:STAT] OFF
OUTP:PROT:DEL *
OUTP:REL[:STAT] OFF
OUTP:REL:POL NORM
TRIG:SOUR BUS
VOLT[:LEV][:IMM] *
VOLT[:LEV][:TRIG] *
VOLT:PROT[:LEV] *
*RST
(None)
(None)
*PSC
*SAV
OUTP[:STAT]
OUTP:PROT:DEL
OUTP:REL[:STAT]
*SAV <NRf>
0|1|2|3
SAV 3
(None)
*RCL *RST
OUTP:REL:POL
VOLT[:LEV][:IMM]
VOLT:PROT[:LEV]
Language Dictionary
69

Advertisement

Table of Contents
loading

Table of Contents