3. S
ETUP

AC Power

Fuse
Replacement
TM
Hurricane
1101 User Manual Rev. 1
TM
This Hurricane
1101 has a fixed voltage power supply and it can work with an input
voltage of either 120 VAC, 60 Hz or 230 VAC, 50 Hz, depending on the specific model.
To determine the product's power requirements (circuit breaker, power outlet, and
wiring), use the current value listed on the label affixed to the product's back panel, or
refer to the product's specifications chart. The listed current rating indicates the
product's average current draw under normal conditions.
Always connect the product to a protected circuit (circuit breaker or fuse). Make
sure the product has an appropriate electrical ground to avoid the risk of
electrocution or fire.
Never connect the product to a rheostat (variable resistor) or dimmer circuit, even
if the rheostat or dimmer channel serves only as a 0 to 100% switch.
1.
Disconnect the product from power.
2.
With a Phillips #2 head screwdriver, unscrew the fuse holder
cap from the housing.
3.
Remove the blown fuse.
4.
Replace with a fuse of the same type and rating.
5.
Screw the fuse holder cap back in place and reconnect
power.
Disconnect the product from power before replacing the fuse.
Always replace a blown fuse with another of the same type and rating.