6. G
T
ENERAL
Symptom
No output or short output
No output or spitting fluid
Fuse keeps blowing
Product does not power
up
Product stops pumping/
Loud noise
TM
Hurricane
1101 User Manual Rev. 1
ROUBLESHOOTING
Possible
Indicator
Cause
Status
Line blockage
or air in fluid
Orange
line
Incorrect fluid
Incorrect fluid
Blocked pipes
Failing part
Excessive load on the circuit
Short circuit along the power
lines
No energy on power outlet
Loose or damaged power cord
Blown fuse
Internal problem
Low/No Fluid
Pump protection system
engaged
If you still experience problems after trying the solutions presented here, contact
Chauvet Technical Support. See Contact Us.
Make sure there is fluid in the tank
Turn fog machine 45° to flatten out the bubble
and allow the fog fluid to flow properly
Prime by setting output to the highest setting
Turn off the product for 5 seconds, and then turn it
back on. Repeat as necessary.
Note: After more than 10 attempts, contact
Customer Service.
Clean thoroughly with CHAUVET® FCQ. For full
Off
instructions, see
CHAUVET® water-based haze fluid.
Clean thoroughly with CHAUVET® FCQ. For full
instructions, see
CHAUVET® water-based haze fluid.
Off
Contact Customer Service
Contact Customer Service
Make sure that the total load does not exceed
80% of the breaker or fuse nominal current
Check the power lines and power cords
Check power outlet
Change to another outlet
Check the power cord
Replace blown fuse with a good one of the same
type and rating
Send product for repair
Refill product with fluid
Release manual fog button, and press it again to
reset pump protection system
Possible Action
Fogger
Maintenance. Refill with
Fogger
Maintenance. Refill with
Page 11 of 11