MAINTENANCE
The grease in the gearbox will
require replenishment after
approximately 50 hours
accumulative use. After this time
add approximately 30 grams of
grease, into the gearbox. First
remove the metal plate and
washer from the tool by removing
the 4 retaining screws using the
allen key (supplied), then remove
the metal cover and washer. Add the grease through this hole. Ensure
the washer and metal cover is put back into position and secured with the
4 allen key screws prior to operation.
After each use, blow air through the tool housing to ensure it is free from
all dust particles that may build up. Build up of dust particles may cause
the tool to overheat and fail.
If the enclosure of the tool requires cleaning do not use solvents but a
moist soft cloth only. Never let any liquid get inside the tool; never
immerse any part of the tool into a liquid.
When the carbon brushes wear out the tool will spark and/or stop. The
brushes are a wearing component of the tool and should be replaced
prior to the carbon wearing out fully. Brushes will wear out after many
uses but before they do take the tool to an Authorised Ozito Service
Agent for quick and low cost replacement. Always replace both brushes
at the same time.
Note: Ozito Industries will not be responsible for any damage or injuries
caused by the repair of the tool by an unauthorised person or by mishandling
of the tool.