ENGLISH
Using the wood burning stove
Adjusting the air damper. The damper has 3 settings.
Control
If the ash is white and the walls in the combustion chamber are soot free after the stove
has been used, the air regulation was set correctly and the wood was sufficiently dry.
RAIS manual for Rais QTee
Position 1
The damper is almost closed meaning that there is a
minimal air intake.
Position 2
Pull / push the lever until the first click. This position
gives full secondary air.
During normal use the lever is set between position 1
and 2.
When the flames are clear and yellow, the damper is
set correctly, i.e. resulting in a slow/optimal burning.
Position 3
Pull / push the lever until the next click.
The air damper is completely open and gives full
primary and secondary air. This position is for the
lighting stage and is not used under normal operation.
24