Make sure you have an appropriate site location and cables prepared with
adequate lengths to connect to main power and other devices.
At least two people will be required to install the chassis. Disk drives should
only be installed after the chassis is properly mounted. The chassis can weigh
about 24Kgs without disk drives.
The following tools are necessary for mounting the chassis:
Use the included M5 or M6 screws for securing the chassis through its front
mounting ears.
More details about the use of optional slide rails are given in the Installation
Guide that came with the slide rail package.

2.7.2 Mounting Holes Positions

Integrators may design their own brackets or slide rails using the twenty-two
(22) mounting holes on the sides of chassis.
There are six (6) mounting holes with six (6) M4 nuts near the end of the chassis
on each side. Shown below are the locations of these mounting holes. (See the
arrow marks in Figure 2-1). See the next diagram for another group of mounting
holes on a horizontal line.
Figure 2-2 shows holes that are designed for slide rail options. There are five (5)
mounting holes for #6-32 screws on the sides of the enclosure for use with slide.
Use M5 or M6 pan-head screws to secure the chassis to the front cabinet posts.
The
2-8
#4 Phillips-head screwdriver
Wrenches may be necessary, depending on the rack type
Figure 2-1: Enclosure Side Mounting Holes (1)
Figure 2-2: Enclosure Side Mounting Holes (2)
front
ear
holes
are
shown
in
Figure
2-3.
Rackmounting