Rorke Data Galaxy Raid GALHDX-7370S-8U4D Installation And Hardware Reference Manual page 56

8 bay scsi u320 to sata-ii raid subsystem
Table of Contents

Advertisement

Figure 4- 2: Single Host Connection: Correct
Connection
A server is connected to one of the host ports.
There is no need for further termination
configuration because the firmware default is
terminator ON, and the auto-sense terminator is
also automatically enabled.
Figure 4- 4: Dual Host Connection: Correct
Connection
The "IN" and "OUT" ports are separately
connected to a server and a cascaded enclosure.
The auto-sense terminator is automatically
disabled, and the firmware setting should be
manually disabled.
The firmware default for SCSI bus termination setting is "ON." The bus termination
setting can be manually enabled or disabled on each SCSI channel. See the diagrams
below for different accesses to the termination control. More details about the
configuration process can be found in the Generic Operation Manual or the
RAIDWatch User's Manual that came with the Product Utility CD.
SCSI Connection Overview
Chapter 4: Connection and Operation
Figure 4- 3: Dual-Host Connection: Incorrect
Connection
The "IN" and "OUT" ports are separately
connected to a server and a cascaded enclosure.
The auto-sense terminator is disabled, while the
firmware setting remains effective. Problems will
occur on the SCSI bus.
4-3

Advertisement

Table of Contents
loading

Table of Contents