Updating Firmware - Yamaha RX-Z9 Service Manual

Av receiver/av amplifier
Hide thumbs Also See for RX-Z9:
Table of Contents

Advertisement

RX-Z9/DSP-Z9

UPDATING FIRMWARE

Equipment required
• PC with RS-232C serial port (OS: Windows 98/2000/Me/
XP)
• Firmware Loading Program (YAV Boot V511.exe)
• Firmware (xxx.mts or xxx.mot file)
• RS-232C cross cable "D-Sub 9-pin Female".
(Specification)
Pin No.2 RxD
Pin No.3 TxD
Pin No.5 GND
Pin No.7 RTS
Pin No.8 CTS
RX-Z9/DSP-Z9 side
• RS-232C Conversion Adapter (Part No.: AAX24910)
Installation procedure of firmware loading program
Download the firmware loading program (YAV Boot.exe) and
firmware (xxx.mts or xxx.mot file) from the specified down-
load sources into the same folder of the PC for updating the
firmware.
UPDATING FIRMWARE
CAUTION
• As updating the main microprocessor will cause the
memory to be initialized, take notes of the parameters
changed by the user before updating and change the pa-
rameters according to these notes after updating. (With
some other microprocessors, the memory will be initial-
ized but not with some others.)
1
Before turning on the power to the amplifier and PC, con-
nect between RS232C ports of both units with the
RS232C cable (cross cable). When updating the firm-
ware from the front panel side, remove the volume knob
and use the RS232C conversion adapter.
76